AR-285 (serv.man12). AR280 285 335 Service Manual-Simulation Codes - Sharp Copying Equipment Service Manual (repair manual). Page 104

Read Sharp AR-285 (serv.man12) Service Manual online

50 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy image position and the void area (image loss) on the print paper in the copy mode.
(Simple adjustment)
(This simulation allows the same simulation with SIM 50-1 more simply. )
Section
Item
Picture quality
Image position
Operation/
Procedure
1. Select the adjustment item with [
], [
] keys.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key. (The value entered in procedure 2 is set.)
IMAGE LOSS
DEN-A
DEN-B
  
 
 



Same as SIM 50-1
This simulation is used to automatically adjust the image loss, the void area, and the image position by directly entering
the paper lead edge and the image shift (in the unit of 0.1mm) in 400% (200% for the SPF) copy.
a. Distance (Document table mode 400%) up to the scale of 10mm from the image lead edge a L3
b. Distance from the paper lead edge to the image lead edge 
 L2
c. Distance from the image lead edge to the scale of 10mm (SPF mode 200%) 
×
 L3
The measurement value is multiplied with 10 to enter.
With the above procedure, the values of RRC-A and RRC-B in SIM 50-1 are automatically calculated and set.
By directly setting the values (actual dimensions [mm] x 10) of IMAGE LOSS, DEN-A and DEN-B, the lead edge image
loss, the lead edge void area, and the rear edge void area can be set.
(Standard)
Code
Adjustment item
Adjustment value
Note
A
L1
Distance between the image lead
edge and the scale of 10mm.
When the image lead edge
position varied depending on the
copy magnification ratio, change
the set value.
B
L2
Distance between the paper lead
edge and the image lead edge.
C
L3
Distance between the image lead
edge and the scale of 10mm (SPF
mode).
When the image lead edge
position varied depending on the
copy magnification ratio, change
the set value.
D
IMAGE LOSS
Lead edge image loss
1.5  to  3.0mm
The greater the set value is, the
greater the image loss is.
E
DEN-A
Lead edge void area
1.5  to  3.0mm
The greater the set value is, the
greater the void area is.
F
DEN-B
Rear edge void area
1.5  to  3.0mm
The greater the set value is, the
greater the void area is.
Note
8 – 102