AR-275 (serv.man2). AR235 and AR275 Technical Launch Pack - Sharp Copying Equipment Handy Guide. Page 19

Read Sharp AR-275 (serv.man2) Handy Guide online

                                                                                        
AR-235/275
 Technical Information Pack
Document Systems Support
19
11.
Firmware Upgrade
The  procedure  of  upgrading  Flash  ROM  versions  of  the  Copier  engine  is  relatively  simple,
requiring  no  specialised  hardware  aside  from  a  Personal  Computer  and  an  RS-232
connecting cable (level converter is not needed).
The  cable  required  for  connecting  the  personal  computer  to  the  copier  is  an  RS-232
crossover  (null-modem)  cable,  which  must  terminate  with  a  9-pin  connector  at  the  copier
end. A suitable cable can be purchased from Maplin Electronics – part number VD76. Please
contact Maplin Electronics directly on 0870 2646000 for more information.
The  following  diagram  represents  the  connection  between  the  Personal  Computer  and  the
copier:
The  copier  should  be  switched  off  whilst  connecting  the  crossover  cable  between  the
interface  circuit  and  the  Personal  Computer,  and  should  remain  off  whilst  the  maintenance
(upgrade)  software  is  being  loaded.  Once  the  maintenance  program  has  started  with  the
correct  password,  it  is  then  possible  to  supply  power  to  the  copier.  If  the  cable  has  been
connected correctly and the software is running properly it should then be possible to see the
upgrade  options  appear  on  the  screen.  Note  that  it  is  possible  to  perform  an  all-area
download,  in  order  to  upgrade  all  flash  ROM  components  (except  PCL),  and  it  is  also
possible  to  upgrade  separate  components  individually  –  Operation  Panel,  E-Sort,  Fax  (if
installed), and Finisher (if installed).
During the maintenance operation, the program will check the version number of the selected
Flash ROM component and will not overwrite contents of Flash ROM if they are more recent
than the files stored on the Personal Computer. To check the firmware versions installed in
the copier, you may perform simulation 22-5.
To complete the upgrade, close the maintenance program and switch copier power off.
Remove crossover cable, switch machine on and then perform simulation 22-5 to check
firmware has been successfully upgraded.