AR-275 (serv.man2). AR235 and AR275 Technical Launch Pack - Sharp Copying Equipment Handy Guide. Page 13

Read Sharp AR-275 (serv.man2) Handy Guide online

                                                                                        
AR-235/275
 Technical Information Pack
Document Systems Support
13
7.
Simulation Codes Activation
Simulation  codes  allow  the  copier  engineer  to  test  certain  operations  of  the  machine,  and
also allow access to counter information and other operational variables. It is implemented to
assist the engineer in support of the product and it is important, therefore, that this mode of
operation is not be disclosed to users.
The key sequence required to enter the copier simulation mode is as follows :
#   -   INTERRUPT   -   CLEAR   -   INTERRUPT
Once in simulation mode, a ‘main’ code and a ‘sub’ code relating to the required operation
must be entered :
Main Code   -   START Key   -   Sub Code   -   START Key
Entering the fax simulations
If  the  optional  fax  kit  (AR-FX4)  has  been  installed,  it  is  possible  to  enter  the  fax  simulation
(diagnostic) mode by use of the following key sequence :
Function
9
*
8
#
7
Using copier simulation mode and then main code 66 also gives access  to fax  simulations.
Refer to service manual for details.