AR-275 (serv.man10). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 46

Read Sharp AR-275 (serv.man10) Service Manual online

AR-235/275 SIMULATION - 37
Operation/procedure
The data received from the line are checked to insure that the following
reception  data  are  identical  to the  judgment data.  If  identical, "OK"  is
notified. If not, "NG."
A judgment is made according to the reception start data. Continuous
coincidence is required.
Note: Executable only when the FAX is installed.
Operation/procedure
The  send/receive  test  is  performed,  and  the  time  required  for  send/
receive of the image data in the test is measured and displayed.
When there are two or more send/receive operations of image data in
one  communication,  only  the  time  of  the  last  send/receive  data  near
the end is measured.
Note: Executable only when the FAX is installed. 
Operation/procedure
The  following  test  sound  is  delivered  to  the  line  and  the  speaker  to
adjust the sound kind and volume.
The send level to the line is the set value of soft SW.
The  set  values  of  the  selected  sound  kind  and  volume  are  written  to
each soft SW.
1.
Sound kinds pattern
NS=No Sound  S=Small  M=Medium  L=Large
2.
Sound volume pattern
S=Small  M=Medium  L=Large
Note: Executable only when the FAX is installed.
Operation/procedure
Read/write  the  time  (year,  month,  day,  min.,  sec.)  on  RTC  of    FAX
PWB.
Note: Executable only when the FAX is installed.
Operation/procedure
The call signal from CI pin is detected to deliver the call sound to the
line and the speaker. The volume of call sound follows the soft SW.
Signal  detection  and  delivery  of  pseudo-call  sound  at  detection  are
executed  until  the  interruption  command  is  provided  by  pressing  the
[BACK] key.
Note: Executable only when the FAX is installed.
66-32
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Receive data check
Receive speed
300bps
Receive data
00
Number of judgment data
100
66-34
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Communication time measurement display
Related soft SW
SW10-1
Setup on the user 
side when executing 
communication
Communication 
means
Picture quality
Density
ECM
Sender information
: Memory send
: Normal Character
: Lighter
: ON
: OFF
Measuring 
range
Send
From flag reception before sending of 
image data until sending of RCP frame
Receive
From flag reception before reception of 
image data until reception of RCP frame
Mode when measuring
Used to make communication not in a 
simulation process but in the normal screen 
and  measure the time.
How to check the time
Enter the simulation for communication time 
check and check the time.
Measuring unit
msec
66-37
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Speaker sound volume adjustment
Related soft SW
SW 86-1, 2 (call sound)
SW 85-1, 2 (line monitor sound)
SW 84-1, 2 (on hook)
SW 88-1, 2 (read end sound)
SW 89-1, 2 (communication end sound)
SW 87-1, 2 (DTMF send sound)
SW75-1, 2 (send end sound length)
SW75-3, 4 (receive end sound length) 
Sound kinds
(Test sound)
Sound volume set value
Sound 
volume
Pattern
0
1
2
3
1
Call sound
NS
S
M
L
01 to 35
2
Lline monitor sound
(Test sound : 
Communication 
signal sound)
NS
S
M
L
01 to 35
3
On hook
(Test sound : 
Communication 
signal sound)
Setting
Disable
S
M
L
01 to 35
4
Read complete 
sound
NS
S
M
L
01 to 35
5
Communication 
end sound
NS
S
M
L
01 to 35
6
DTMF signal send 
sound
NS
S
M
L
01 to 35
Sound 
volume
VR set value
Sound 
volume
VR set value
1
2
3
4
5
6
7
1
2
3
4
5
6
7
01
S
M
L
20
S
M
L
02
S
M
L
21
S
M
L
03
S
M
L
22
S
M
L
04
S
M
L
23
S
M
L
05
S
M
L
24
S
M
L
06
S
M
L
25
S
M
L
07
S
M
L
26
S
M
L
08
S
M
L
27
S
M
L
09
S
M
L
28
S
M
L
10
S
M
L
29
S
M
L
11
S
M
L
30
S
M
L
12
S
M
L
31
S
M
L
13
S
M
L
32
S
M
L
14
S
M
L
33
S
M
L
15
S
M
L
34
S
M
L
16
S
M
L
35
S
M
L
17
S
M
L
18
S
M
L
19
S
M
L
66-38
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Time setting/check
66-41
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
CI signal check
Related soft SW
SW12-6 to 7, SW55-1 to 7
Page of 58
Display

Click on the first or last page to see other AR-275 (serv.man10) service manuals if exist.