AR-235/275 SIMULATION - 36
Operation/procedure
The send test of dial pulse and DTMF signal is performed and the
make time adjustment of dial pulse and the DTMF signal send level
adjustment are performed if necessary.
make time adjustment of dial pulse and the DTMF signal send level
adjustment are performed if necessary.
• Used to set the make time. By performing the test, the registered
dial pulse of max. 100 digits can be sent from the line.
• When "*" and "#" are included in the registered dial number, they are
disregarded and the number is not processed as a dial.
• The make time set in the dial test is written into the corresponding
soft SW.
• Default: 1 2 3 4 5 6 7 8 9 0
Operate the [
←
] [
→
] key in DP dial selection menu to switch.
(Time before pulse delivery can be changed as 2sec
→
4s ec
→
8sec.)
• Set the signal send level to 0dB or the soft SW set value.
Used to set the high level group and the low level group of DTMF
signal send level. By executing the test, DTMF signal is sent from
the line to a recorded dial number of max. 100 digits.
signal send level. By executing the test, DTMF signal is sent from
the line to a recorded dial number of max. 100 digits.
• The high group/low group value of the DTMF signal send level set in
the dial test is written into the corresponding soft SW.
• Default: 1 2 3 4 5 6 7 8 9 * 0 #
In the PB dial select menu, press [
←
][
→
] keys to select.
Pressing the [CLEAR] key during the operation clears the input
value and returns to the value input menu.
value and returns to the value input menu.
• Max. 100 digits can be assigned to each dial (0 - 9, *, #). While the
default value is displayed at first, a desired value can be entered and
the entered value is stored on the FAX side until the menu is can-
celed.
the entered value is stored on the FAX side until the menu is can-
celed.
• After completion of the mode, the signal send level is returned to the
soft SW set value before execution of the mode.
Note: Executable only when the FAX is installed.
Operation/procedure
Set the signal send level to 0dB or the soft SW set value, and specify
one dial to be delivered to.
one dial to be delivered to.
The DTMF signal of the specified dial number is delivered until the
interruption command is provided by pressing the [BACK] key.) When
another dial number is specified during delivery of the signal, the new
dial number is delivered.
interruption command is provided by pressing the [BACK] key.) When
another dial number is specified during delivery of the signal, the new
dial number is delivered.
The signal send level is returned to the soft SW set value before exe-
cution of the mode after completion of the mode.
cution of the mode after completion of the mode.
Note: Executable only when the FAX is installed.
Operation/procedure
The following FAX information is printed.
Note: Executable only when the FAX is installed.
Operation/procedure
By selection of the sound volume number, the sound volume of the
handset can be set or changed. The set value is written into the soft
SW.
handset can be set or changed. The set value is written into the soft
SW.
During execution of the simulation, the reply sound message for auto
selection of TEL/FAX, "Hold the line for a while," is delivered.
selection of TEL/FAX, "Hold the line for a while," is delivered.
Note: Executable only when the FAX is installed.
Operation/procedure
When the relay state of the polarity reverse relay, the handset hook
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup. The display of
change is kept until an interruption command is supplied by pressing
the [BACK] key.
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup. The display of
change is kept until an interruption command is supplied by pressing
the [BACK] key.
Note: Executable only when the FAX is installed.
66-13
Purpose
Adjustment/Setting/Check
Function
(Purpose)
(Purpose)
Send test and adjustment of the dial pulse and
DTMF signal.
DTMF signal.
Related soft SW
SW53-1 to 4 (DTMF high group end level)
SW53-5 to 8 (DTMF low group send level)
SW67-1 to 4 (DP 10PPS make time)
SW67-5 to 8 (DP 10PPS make time)
SW53-5 to 8 (DTMF low group send level)
SW67-1 to 4 (DP 10PPS make time)
SW67-5 to 8 (DP 10PPS make time)
1. Dial pulse (10pps) send test
2. Dial pulse (20pps) send test
3. DTMF signal send test
Make time
1ms for input value of 1. Adjust so that the dial pulse
make rate is within 33±3%. (For North America,
40±3%.)
Dial pulse make rate =
make rate is within 33±3%. (For North America,
40±3%.)
Dial pulse make rate =
Make time / (Make time + Break time)
Break time
It is obtained from the formula below and
automatically set.
PPS = 1000 / (make time + break time)
automatically set.
PPS = 1000 / (make time + break time)
DTMF signal
adjustment
adjustment
The signal send levels are classified into the high
group and the low group. The send level is 0.5dB for
each 1 of input value.
group and the low group. The send level is 0.5dB for
each 1 of input value.
66-17
Purpose
Adjustment/Setting/Check
Function
(Purpose)
(Purpose)
DTMF signal send
Related soft SW
SW53-1 to 4 (DTMF high group end level)
SW53-5 to 8 (DTMF low group send level)
SW53-5 to 8 (DTMF low group send level)
66-21
Purpose
Adjustment/Setting/Check
Function
(Purpose)
(Purpose)
FAX information print
Print information
Details
A
User switch list
B
Soft SW list
C
Dump list
D
System error
Used to print the system error log (error
number and time). For this operation, the
system error log is always stored as the
ring buffer in the SRAM 256byte area.
number and time). For this operation, the
system error log is always stored as the
ring buffer in the SRAM 256byte area.
E
Protocol monitor
Regardless of soft SW19-1 status, the
protocol monitor of the preceding
communication is printed. (Printing is
allowed at any time before starting the
next communication.) For this operation,
the protocol monitor of one
communication is always buffered.
protocol monitor of the preceding
communication is printed. (Printing is
allowed at any time before starting the
next communication.) For this operation,
the protocol monitor of one
communication is always buffered.
66-22
Purpose
Adjustment/Setting/Check
Function
(Purpose)
(Purpose)
Handset sound volume adjustment
Related soft SW
SW13-1 to 2
Sound volume number
Sound volume
1
Small
2
Medium
3
Large
66-30
Purpose
Adjustment/Setting/Check
Function
(Purpose)
(Purpose)
Recognize TEL/LIU state change.
Check signal
Notification contents
Signal low
Signal high
HS2
ON
OFF
HS1
ON
OFF
RHS
ON
OFF
EXHS
ON
OFF