AR-235/275 SIMULATION - 3
2. Simulation code list
11
Used to set the number of 
times, the magnification 
ratio, and the original 
size, and check the 
operations.
(SPF unit)
Input menu of the 
number of times
Select the mode with the 10-key and press the [OK] key, and the menu shifts to the 
magnification ratio and original size setup menu.
Magnification ratio 
and original size 
setup menu
Select the magnification ratio with [
][
] keys. (Fixed magnification ratio)
Set the magnification ratio to a desired level with [
][
] keys. (1% increment)
Select the original size with the [PAPER SIZE] key.
Select Single/Duplex with the [DUPLEX] key.
Pressing the [OK] key shifts to the execution display.
Pressing the [BACK] key returns to the input menu of the number of times.
Execution menu
The SPF unit is moved at the speed corresponding to the set magnification ratio and the 
original size.
During execution, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the setup menu of the 
magnification ratio and the original size.
12
Used to select the mode 
and check the operations.
(Shifter)
Mode selection menu
Select the mode with the 10-key and press the [OK] key.
When 1 is selected, the menu shifts to the execution menu. When 2 is selected, the 
menu shifts to the input menu.
Execution menu
During execution, [EXEC] is highlighted. 
Pressing the [BACK] key interrupts the operation and returns to the mode selection 
menu.
Input menu
Pressing [
] key shifts the position toward R side by the specified steps.
Pressing [
] key shifts the position toward F side by the specified steps.
Pressing [
] key shifts the home position.
Pressing the [BACK] key returns to the mode selection menu.
No.
Simulation operation and 
procedure pattern
Screen type
Operations and procedures common to every pattern
Code
Function
Main
Sub
1
1
Used to check the operation of the scanner unit 
and its control circuit.
2
Used to check the operation of sensor and 
detector in the scanning (read) section and the 
related circuit.
2
1
Used to check the operation of the SPF unit and 
the related circuit.
2
Used to check the operation of sensors and 
detectors in the SPF unit and the related circuit.
3
Used to check the operation of the loads in the 
SPF unit and the control circuits.
3
2
Used to check the operation of sensor and 
detector in the finisher and the related circuit.
3
Used to check the operation of the load in the 
finisher and the control circuit.
6
Used to adjust the finisher jogger position.
7
Used to adjust the offset tray operations.
11
Used to check the operation of the shifter.
4
2
Used to check the operation of sensor and 
detector in the option tray and the related circuit.
3
Used to check the operation of the load in the 
option tray and the control circuit.
5
1
Used to check the operation of the display, LCD in 
the operation panel, and control circuit.
2
Used to check the operation of the heater lamp 
and the control circuit.
3
Used to check the operation of the copy lamp and 
the control circuit.
6
1
Used to check the oepration of the loads (clutches 
and solenoids) in the paper transport system and 
the control circuit.
2
Used to check the operation of each fan motor and 
its control circuit.
7
1
Used to set the aging operation conditions.
6
Used to set the cycle of intermittent aging.
8
Used to set the display of the warm-up time.
8
1
Used to check and adjust the operation of the 
developing bias voltage in each copy mode and 
the control circuit.
2
Used to check and adjust the operation of the main 
charger grid voltage (high mode) in each copy 
mode and the control circuit.
3
Used to check and adjust the operation of the main 
charger grid voltage (low mode) in each copy 
mode and the control circuit.
10
Used to check and adjust the operation of the 
developing bias voltage in each printer mode and 
the control circuit.
11
Used to check and adjust the operation of the main 
charger grid voltage (high mode) in each printer 
mode and the control circuit.
12
Used to check and adjust the operation of the main 
charger grid voltage (low mode) in each printer 
mode and the control circuit.
13
Used to check and adjust the operation of the 
developing bias voltage in FAX mode and the 
control circuit.
14
Used to check and adjust the operation of the main 
charger grid voltage (high mode) in FAX mode and 
the control circuit.
15
Used to check and adjust the operation of the main 
charger grid voltage (low mode) in FAX mode and 
the control circuit.
9
1
Used to check and adjust the operation of the load 
(motor) in the duplex section and the control 
circuit.
4
Used to adjust the rotation speed of the duplex 
motor.
5
Used to adjust the switch back time of the duplex 
motor.
10
0
Used to check the operation of the toner motor and 
its control circuit.
14
0
Used to cancel excluding the self-diag U2/PF 
troubles.
16
0
Used to cancel the self-diag U2 trouble.
17
0
Used to cancel the self diag "PF" trouble.
21
1
Used to set the maintenance cycle.
Code
Function
Main
Sub