AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 38

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 SIMULATION - 29
When initializing each data: 50
Note: Executable only when the FAX is installed.
Operation/procedure
The FAX exposure level can be adjusted separately for each mode by
specifying a sub code. Since selection of Auto/Manual and Photo ON/
OFF is allowed separately for each mode, adjustments of 14 patterns
in total can be made. 
(Refer to 46-12, "Exposure adjustment table".)
Shading is performed to turn on the copy LED.
The current exposure value of the selected mode is displayed.
Enter  the  2-digit  adjustment  value  with  the  10-key  pad  and  push
START key. The entered value  is set for the specified mode,  and the
self print is made with the same magnification ratio for the mode.
Note: Executable only when the FAX is installed.
Operation/procedure (Pattern 5)
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When  the  [START]  key  is  pressed,  a  print  is  made  and  the  display
returns to the mode selection menu.
(Auto adjustment)
Setup of various copy conditions: Similar to the normal copy mode.
Use  of  [SPECIAL  FUNCTION]  key,  [JOB  STATUS]  key,  and  [INTER-
RUPT] key is inhibited.
Operation/procedure (Pattern 2)
Select the mode with the 10-key and press the [OK] key.
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Pressing the [BACK] key returns to the mode selection.
Auto exposure mode
• When  SIM  26-6  (Destination  setup)  is  changed  from  EX  to  Japan,
the setup value becomes 1 (Default: Japan). If, on the contrary, it is
changed from Japan to EX, the set value becomes 2 (Default: EX)
• If the auto exposure mode setup value is changed, the setup value
of SIM 46-30 (AE limit setup) is reset to the default value.  
Operation/procedure (Pattern 2)
Select the mode with the 10-key and press the [OK] key.
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Pressing the [BACK] key returns to the mode selection.
Mode
AE
Photo
Exposure adjustment
STD
(Standard 
character)
Auto
ON
Manual
Auto
OFF
Individual adjustment 
enable
(46-13 to 16)
Manual
Fine
(Small 
character)
Auto
ON
Manual
Auto
OFF
Manual
S-fine
(Fine)
Auto
ON
Manual
Auto
OFF
Manual
U-fine
(Super fine)
Auto
ON
Manual
Auto
OFF
Manual
46-13 to 16
Purpose
Adjustment
Function 
(Purpose)
FAX exposure level adjustment (individual)
Sub code
Mode
13
STD (normal character)
14
Fine (small character)
15
S-fine (super fine)
16
U-fine (super fine)
46-18
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the copy contrast. (Inclination)
Item
Picture quality
(Initial screen)
(Input screen)
(Executing screen)
Sim46-18 GAMMA SET.
1:AE             
50
2:TEXT           50
3:TEXT/PHOTO     50
1/3              
50
Display items
Content
Setting 
range
Default
1:AE
AE
1-99
50
2:TEXT
Character
Level 3.0
3:TEXT/PHOTO
Character/Photo
Level 3.0
4:PHOTO
Photo
Level 3.0
5:SUPER PHOTO
Super photo
Level 3.0
6:AE(TS)
AE(TS)
7:TEXT(TS)
Character (TS)
Level 3.0
8:TEXT/PHOTO(TS)
Character/Photo (TS)
Level 3.0
46-19
Purpose
Adjustment
Function 
(Purpose)
Used to change the image quality in the exposure 
mode.
Item
Picture quality
(Initial screen)
(Input screen)
Display items
Content
Default
1:AE MODE
(1:EXPOSURE
2:TONER)
Auto exposure mode
(1: Priority on Image quality, 
2: Priority on toner consumption)
2
2:AE STOP(COPY)
(0:FIXED
1:REAL TIME)
Auto exposure STOP mode (COPY)
(0: Fixed, 1: Real-time)
0
3:AE STOP(FAX)
(0:FIXED
1:REAL TIME)
Auto exposure STOP mode (FAX)
(0: Fixed, 1: Real-time)
0
4:AE STOP(SCAN)
(0:FIXED
1:REAL TIME)
Auto exposure STOP mode 
(SCANNER)
(0: Fixed, 1: Real-time)
0
5:1200dpi PHOTO
(1:SOFT
2:HARD)
1200dpi photo mode 
(Countermeasures for claims on 
dither)
(1: Soft mode, 2: Hard mode)
1
46-20
Purpose
Adjustment
Function 
(Purpose)
Used to correct SPF exprosure.
Item
Picture quality
Sim46-19 AE MODE
1:AE MODE        
 
1
2:AE STOP(COPY)   0
3:AE STOP(FAX)    0
1/2             
  1
Sim46-19 AE MODE
1:AE MODE         1
 (1:EXPOSURE
  2:TONER)
     [  1-  2]  
  1
Page of 58
Display