2. Details of trouble codes
Main 
code
Sub
code
Detail of trouble
E7
03
Content
LSU trouble
Detail
After the polygon motor becomes
active, BD signal (HSYNC) from the
LSU is not detected at the specified
times (41 
±
 10 times within 20msec).
Cause
LSU connector disconnection or LSU’s
inside harness disconnection or
breakage
Polygon motor rotation abnormality
Improper positioning of the laser home
position sensor in the LSU.
Laser power voltage failure
Laser emitting diode abnormality
MCU PWB abnormality
Check and
remedy
Improper connection of the LSU
connector
Check the polygon motor operation
with SIM 25-10.
Check printing with SIM64-1.
Check laser emission of laser emitting
diode.
Check the LSU unit.
Check the MCU PWB.
04
Content
CCD white level trouble
Detail
CCD white reference level which is
read during the copy lamp lighting is
abnormal.
Cause
Flat cable installation failure to CCD unit
Dirt on the mirror, lens, and reference
white plate
Copy lamp lighting failure
CCD unit installation failure
CCD unit abnormality
MCU PWB abnormality
Check and
remedy
Clean the mirror, the lens, and the
reference white plate. 
Check the copy lamp (SIM 5-3) ON.
CCD unit check
MCU PWB check
05
Content
CCD black level trouble
Detail
CCD black level which is read while the
copy lamp is off is abnormal.
Cause
Flat cable installation failure
CCD unit abnormality
MCU PWB abnormality
Check and
remedy
Check flat cable installation to the CCD
unit.
CCD unit check
MCU PWB check
F1
06
Content
Shift motor abnormality
Detail
The rotation pulse is not detected for
0.5sec or more during rotation of the
shifter motor.
Cause
Motor lock
Motor rotation abnormality
Overcurrent to the motor
MCU abnormality
Check and
remedy
Check the operation of the shifter motor
with SIM 3-3.
H2
00
Content
Thermistor open detection
Detail
Fusing thermistor open
Main 
code
Sub
code
Detail of trouble
H2
00
Cause
Thermistor defect
MCU PWB defect
Fusing section connector contact failure
Power failure
Fusing unit not installed
Check and
remedy
Check the harness and the connector
of the thermistor and the MCU.
Clear the self diag display with SIM 14. 
H3
00
Content
Heat roller abnormally high temperature
Detail
Fusing temperature of 220 
 240˚C.
Cause
Thermistor defect
MCU PWB defect
Fusing connector connection failure
Power failure
Check and
remedy
Check the heater lamp blinking with
SIM 5-2. 
When the lamp blinks normally:
Check the thermistor and the
harness. Check the MCU PWB
thermistor input circuit.
When the lamp lights up instead of
blinking:
Check the lamp control circuit of the
power PWB and the MCU PWB.
Clear the trouble with SIM 14. 
H4
00
Content
Heat roller abnormally low temperature
Detail
When the temperature does not reach
155˚C within 55 sec after turning on the
power, or when it falls under 145˚C
during printing, or when it falls under
100˚C during pre-heating.
Cause
Thermistor failure
Heater lamp failure
MCU PWB failure
Thermostat failure
Power failure
Interlock switch failure
Check and
remedy
Check blinking of the heater lamp with
SIM 5-2. 
When the lamp blinks normally:
Check the thermistor and the
harness.
Check the MCU PWB thermistor
input circuit.
When the lamp does not light:
Check for heater lamp
disconnection or thermostat
disconnection.
Check the interlock switch.
Check the power PWB and MCU
PWB lamp control circuit.
Clear the trouble with SIM 14. 
L1
00
Content
Mirror base feed trouble
Detail
The mirror home position (MHPS) does
not turn off though the feed operation is
completed during mirror initial operation
after turning on the power.
The mirror home position (MHPS) does
not turn off during shading operation.
The mirror home position (MHPS) does
not turn on when the mirror base is
returned for the specified time after
copy feed is started and SPF scanning
position shift is performed.
AR-200