(3) Move the TN-LEV in the direction of the arrow, and remove it from the holes.
(4) Remove the spring from the old TN-LEV, and attach the new TN-LEV.
(5) Attach the TN-LEV to the WTN-COV-U.
Note : Make sure that the boss of the TN-LEV lies between the two ribs of the WTN-
COV-U.