AR-156. AR120E 121E 150 151 155 156 F151 - Sharp Copying Equipment Handy Guide. Page 21

Read Sharp AR-156 Handy Guide online

User Programs
Version 2.0
Issue 05/00
21
SHARP ELECTRONICS (UK)  LTD
COPIER TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
CUSTOM SETTINGS (Key Operator/User Programs)
Auto Power Off Setting
Pre-Heat Timer Setting
Auto clear time
Stream feed (SPF models)
Auto power off setting
The User Programs allow the parameters of certain functions to be set, reset,
changed or cancelled as desired.
User Program Modes Entry
Press and hold the right and left EXPOSURE ADJUSTMENT KEYS
simultaneously for 5 seconds.
The Drum, Jam, Toner & Maintenance lamps will flash at the same time and
“- -“ will show in the copy quantity display.
The following chart shows which programs can now be selected.  Enter the function
name value followed by the set code value.
FUNCTION
NAME 1
SET
CODE
FUNCTION
NAME 2
SET
CODE
FUNCTION
NAME 3
SET
CODE
FUNCTION
NAME 4
SET
CODE
FUNCTION
NAME 5
SET
CODE
0
(Cancel
)
0
(30
secs)
0
(2 mins)
0
(Cancel)
0
(Cancel)
1
(30
secs)
1
(60
secs)
1
(5 mins)
1
(Set)
1
(Set)
2
(60
secs)
2
(90
secs)
2
(15 mins}
3
(90
secs)
3
(30 mins)
4
(120
sec)
4
(60 mins)
Auto
Clear
5
(10
secs)
Pre-heat
Auto
Shut
Off
5
(120min)
Stream
Feed
(With
Doc
Feed)
Auto
Shut off
Setting
1) Auto clear-Elapsed time between job completion and the machine returning to standard conditions.
2) Pre heat mode setting – Elapsed time between job completion and the machine entering pre-heat mode.
3) Auto shutoff – Elapsed time between job completion and the machine switching to Shut Down.
4) Stream feed – Selection or de-selection of stream feeding mode when using the document feeder
5) Auto shut-off setting – Selection or de-selection of auto shut off mode  shown in 3)
Page of 28
Display