AL-1566 (serv.man17). Service manual - Sharp Copying Equipment Service Manual (repair manual). Page 15

Read Sharp AL-1566 (serv.man17) Service Manual online

AL-1556/1566  CONSUMABLE PARTS  3 - 1
[3] CONSUMABLE PARTS
1. Supply system table 
Common to all destinations
2. Environmental
The environmental conditions for assuring the copy quality and the machine operations are as follows:
(1) Normal operating condition
Temperature:20 - 25°C
Humidity:65 ± 5%RH
(2) Acceptable operating condition
(3) Transport condition
(4) Supply storage condition
No.
Name
Content
Life
Product name
Package
1
TD cartridge (Black) 4K
Toner/developer cartridge x 1
(Toner: Net weight 124g) (Developer: Net weight 190g)
4K
A4 size at 5% coverage
AL-110DC
5
2
Drum cartridge
Drum cartridge x 1
18K
AL-100DR
5
Humidity (RH)
85%
60%
20%
10˚C
30˚C
35˚C
Humidity (RH)
90%
60%
15%
–25˚C
30˚C
40˚C
Humidity (RH)
90%
20%
–5˚C
45˚C
Page of 127