Read Sharp AL-1566 (serv.man13) Service Manual online
AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 13
26
38
Cancel of stop at drum life
over (DRUM LIFE END)
over (DRUM LIFE END)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK/START] key to save the setting.
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
The operation is similar to test command 21-01.
39
Memory capacity check
(MEM.CHK)
(MEM.CHK)
[Function]
When the test command is executed, the currently installed SDRAM of the main unit is displayed.
When the test command is executed, the currently installed SDRAM of the main unit is displayed.
[Operation]
40
Polygon motor OFF time
setting (Time required from
completion of printing to
turning OFF the motor) (LSU
MOTOR OFF)
setting (Time required from
completion of printing to
turning OFF the motor) (LSU
MOTOR OFF)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK/START] key to save the setting.
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
The operation is similar to test command 21-01.
42
Transfer ON timing control
setting (TC ON TIMING)
setting (TC ON TIMING)
[Function]
When this test command is executed, the currently set value of the transfer ON timing is displayed
(initial display), and the set value is saved. (Setting range: 0 – 9, Default: 5)
When this test command is executed, the currently set value of the transfer ON timing is displayed
(initial display), and the set value is saved. (Setting range: 0 – 9, Default: 5)
∗
The default “5” of transfer ON timing is “330ms passed from PS release.”
∗
When set to “0,” it is the same as setting to “5.”
[Operation]
The operation is similar to test command 21-01.
Main
code
code
Sub
code
Contents
Details of function/operation
Code number
Setting
Display item
Remark
0
Stop at drum life over
STOP
Default
1
Cancel of stop at drum life over
NONSTOP
Code number
Setting
Remark
8
8 MBYTE
1) Memory capacity display
26-39 MEM.CHK
8 MBYTE
Code number
Setting
Display item
Remark
0
0sec
0 SEC.
1
30sec
30 SEC.
Default
2
60sec
60 SEC.
3
90sec
90 SEC.
Code
Setting
Remark
0
0 msec
1
–40 msec
2
–30 msec
3
–20 msec
4
–10 msec
5
0 msec
Default
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
Click on the first or last page to see other AL-1566 (serv.man13) service manuals if exist.