AL-1566 (serv.man11). Disassembly and assembly - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AL-1566 (serv.man11) Service Manual online

AL-1556/1566  DISASSEMBLY AND ASSEMBLY  8 - 4
8) Move the carriage to the position indicated on the figure.
9) Loosen the screw which is fixing the tension plate.
10) Move the tension plate in the arrow direction to release the ten-
sion, and remove the belt.
11) Remove the screw, and remove the rod stopper.
12) Remove the rod.
13) Lift the rear side of the carriage, remove the belt and the connec-
tor, and remove the carriage.
C. Assembly procedure
CCD core
1) Pass the core through the CCD-MCU harness. 
2) Insert the CCD-MCU harness into the CCD PWB connector of the
carriage unit. 
3) Move the core which was passed through the CCD-MCU harness
near the CCD PWB connector as shown in the figure below, and fix
it with a filament tape (19mm wide, 40mm long). For the attach-
ment reference, refer to the figure below. Clean and remove oil
from the attachment section.  
4) Attach the CCD-MCU harness to the duplex tape on the back of
the carriage unit.
5) Attach the PWB holder to the position specified in the figure below.
6) Pass the core through the FFC and the PWB holder, and fix the
core.
1)
2)
4)
3)
1)
2)
3)
1)
2)
4)
3)
Note: Attach the FCC to the base 
plate securely with duplex tape 
to prevent against coming loose.
Note: Attach the FCC to 
fit with the marking line.
Marking line.