AL-1555 (serv.man27). Sect. 6 Special Functions - Sharp Copying Equipment User Guide / Operation Manual. Page 4

Read Sharp AL-1555 (serv.man27) User Guide / Operation Manual online

55
6
2
Press and hold down the exposure mode 
selector key for approximately 5 seconds. 
The manual (
) indicator will go out 
and the photo (
) indicator will begin to 
blink. The exposure indicator marked "5" 
will light up, indicating the standard toner 
mode is active.
3
To enter the toner save mode, press the 
light (
) key. The exposure indicator 
marked "1" will light up, indicating the 
toner save mode is selected.
4
Press the exposure mode selector key. The photo (
indicator will stop blinking and the exposure indicator marked 
"3" will light up. The toner save mode is now active.
USER PROGRAMS
The user programs allow the parameters of certain functions to be set, changed, or 
canceled as desired.
Setting the power save modes, auto clear time, stream 
feeding mode and resolution of AUTO & MANUAL mode
1
Press and hold down the light (
) and dark (
) keys 
simultaneously for more than 5 seconds until all the alarm 
indicators (
 , 
) blink and "
" appears in the display.
2
Use the left copy quantity (
) key to select a user program 
number (1: auto clear time, 2: preheat mode, 3: auto power 
shut-off timer, 4: stream feeding mode, 5: auto power shut-off 
mode 6: resolution of AUTO & MANUAL mode). The selected 
number will blink in the left side of the display.
3
Press the start (
) key. The entered program number will be 
steadily lit and the currently selected parameter number for the 
program will blink on the right side of the display.
4
Select the desired parameter using the right copy quantity (
key. The entered parameter number will blink on the right of the 
display.
To return to the standard mode, repeat the procedure but use the dark 
(
) key to select exposure level "5" in step 3.
Page of 5
Display

Click on the first or last page to see other AL-1555 (serv.man27) service manuals if exist.