AL-1000, AL-1010 (serv.man12). AL1000 Simulation, Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AL-1000 / AL-1010 (serv.man12) Service Manual online

Main code
Main code
Main code
30
1
Paper sensor status display
(Operation/Procedure)
The paper sensor status is displayed on the copy quantity display.
Sensor name
Display lamp
Resist front paper sensor(PPD1)
Developing lamp replacement lamp
Fusing section paper sensor (PPD2)
JAM lamp
Paper exit sensor (PDD)
OPC drum cartridge replacement lamp
New drum cartridge sensor (PUIS)
Zoom lamp
2nd CS paper sensor (PPD3)
2nd cassette lamp
Single manual feed paper detection(MFD)
AE lamp
43
1
Fusing temperature setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed. 
2. Enter the code number and press the START key, and the setting will be changed.
Code number
Set temperature (°C)
0
175
1
180
2
185
3
190 (*Default)
4
195
5
200
4
Multi copy fusing temperature setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed. 
2. Enter the code number and press the START key, and the setting will be changed.
Code number
Set temperature (°C)
0
155
1
160
2
165 (*Default)
3
170
4
175
5
180
* To suppress temperature rise in the machine during multi copying,the fusing temperature is automatically
changed from the level set with SIM 43-1 to the level set with this simulation after 20 sheets of multi copy.
46
1
Copy density adjustment
(Outline)
Used to adjust the copy density in each copy mode.(The copy density can be set by changing the set value of
ASIC GAMMA ADJUST register.)
Setting in each copy mode is performed at exposure level 3. When the copy density (exposure) is adjusted
arbitrarily, the max, and min. exposure levels are automatically calculated and set. (The change amounts
(gradient, change amount) at level 1 - 5 are predetermined.)
(Operation/Procedure)
1. When this simulation is executed, warming up and shading are performed and the current set value is
displayed in two digits.
2. Press the copy mode select key to select each setting mode and setting display. 
* The copy mode setting is indicated with the following lamps as shown below.
3. Change the setting with the value up-down key and press the START key, and a copy will be made with the
entered set value.
4. Press the clear key to store the set value and exit the simulation. 
Copy mode
Display lamp
AE mode
AE mode lamp
TEXT mode
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE)
AE mode lamp & PHOTO mode lamp
AL-1000/1010
10-7
Page of 15
Display

Click on the first or last page to see other AL-1000 / AL-1010 (serv.man12) service manuals if exist.