AL-1000, AL-1010 (serv.man11). AL1000 Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp AL-1000 / AL-1010 (serv.man11) Service Manual online

(4) Features of copy density adjustment
For the copy density adjustment, the image data shift function
provided in the image process LSI is used.
List of the adjustment modes
Auto Mode
Brightness 1 step only
Manual Mode
Brightness 5 steps. Adjustment of only
the center brightness is made. 
Photo Mode
Brightness 5 steps. Adjustment of only
the center brightness is made.
 
Manual T/S
mode
Brightness 5 steps. Adjustment of only
the center brightness is made. 
T/S Auto
mode
Brightness 1 step only
(5) Copy density adjustment procedure
Use SIM 46-01 to set the copy density for each copy mode. 
For selection of modes, use the copy mode select key. 
A. Test chart (UKOG-0162FCZZ) setting
1) Place the test chart so that its edge is aligned with the A4
(Letter) reference line on the document table. Then place a
B4 (14
 
×
 8 1/2
) white paper on the test chart and close the
document cover.
B. Perform the adjustment in each mode.
(1) Execute SIM 46-1.
(2) Select the mode to be adjusted with the exposure mode
select key. Set the exposure level to 3 for all adjustment.
(Except for the auto mode.)
Adjustment
mode
Exposure mode
display lamp
Ex-
posure 
level
Sharp gray chart
adjustment level
Auto mode
Auto lamp ON
“3” is slightly
copied.
Manual
mode
Manual lamp ON
3
“3” is slightly
copied.
Photo mode
Photo lamp ON
3
“3” is slightly
copied.
Manual T/S
mode
Manual
lamp/Photo lamp
ON
3
“4” is slightly
copied.
Auto T/S
mode
Auto lamp/Photo
lamp ON
3
“4” is slightly
copied.
(3) Make a copy. 
Check the adjustment level (shown in the above table) of the
exposure test chart (Sharp Gray Scale).
Sharp Gray Scale adjustment level
Non toner
save mode
Toner save
mode
(When too bright): Decrease the value displayed on the
copy quantity display. 
(When too dark): Increase the value displayed on the copy
quantity display.
* The value can be set in the range of 1 — 99.
Test chart
White paper
(1)
(2)
(1) Mode select key/display 
lamp
(2) Exposure level select 
key/display lamp
1
10
W
2
3
4
5
6
7
8
9
Slightly copied.
Not copied.
1
10
W
2
3
4
5
6
7
8
9
Slightly copied.
Not copied.
AL-1000/1010
9-9
Page of 14
Display