PN-Y325 - Sharp Monitor Service Manual (repair manual). Page 22

Read Sharp PN-Y325 Service Manual online

PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING    2 - 6 
 
[Communication conditions] 
Set the RS-232C communication settings on the PC to match the monitor’s communication settings as follows: 
 
 
[Communication procedure] 
Command format 
When a command is sent from the PC to the monitor, the monitor operates according to the received command and sends a response 
message to the PC. 
Daisy chain connection… Advanced operation 
 
Do not use spaces for DATE. Specify parameters using a specified number of characters. 
If a command has “R” listed for “DIRECTION” in the “RS-232C command table” on page 35, the current value can be returned by using “?” 
as the parameter. 
 