CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-R903/R703/R603 
DISASSEMBLY AND ASSEMBLY
 6 – 13
2 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
    
0.5 - 0.65N•m
■ PN-R703/R603
1 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
    
0.4 - 0.58N•m
Screw x 6