PN-R903 (serv.man5) - Sharp Monitor Service Manual (repair manual). Page 119

Read Sharp PN-R903 (serv.man5) Service Manual online

CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-R903/R703/R603 
DISASSEMBLY AND ASSEMBLY
 6 – 9
4 ) Remove four screws A(M3 x 6, Black) and eight hexagonal screws B.  Then, remove the IF angle L and the IF angle S.
IF PWB can be removed anly after you remove the IF angles.  
CAUTION
SCREW TIGHTENING TORQUE
    
Screw A/B : 0.55 - 0.65N•m
■ PN-R703/R603
1 ) Remove six screws A (M3 x 6 BIND) and eight screws B (M3 x 6 SW+W, Silver). Remove the EMI sheet A/B and the main IF cover. 
CAUTION
SCREW TIGHTENING TORQUE
    
Screw A: 0.7 - 0.9N•m
    
Screw B: 0.55 - 0.65N•m