CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-L702B DISASSEMBLY AND ASSEMBLY
 6 – 13
12. AC RELAY UNIT
1 ) Disconnect four connectors, remove four screws (M3 x 6 SW+W, Silver), and remove the AC relay unit.
CAUTION
SCREW TIGHTENING TORQUE
n
0.7 - 0.9N•m
13. INLET HARNESS/AC SWITCH
1 ) Disconnect four connectors, remove one screw A (M4 x 6, Silver), and remove the AC switch. Remove two screws B (M3 x 6 countersunk,
Black), and remove the AC inlet cable. 
CAUTION
SCREW TIGHTENING TORQUE
n
Screw A: 0.9 - 1.1N•m
n
Screw B: 0.7 - 0.9N•m
Screw x 4
Connector x 4
Black
White
White
Blue
Confirm that the circle 
(o) is on the left side 
and it is in the OFF 
Screw x 2
AC Inlet Cable
AC Switch
Mark
When attaching, ensure that the 
terminals are oriented as 
indicated in the engraved mark.
A
Screw
x 1