CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-L702B DISASSEMBLY AND ASSEMBLY
6 – 13
12. AC RELAY UNIT
1 ) Disconnect four connectors, remove four screws (M3 x 6 SW+W, Silver), and remove the AC relay unit.
CAUTION
SCREW TIGHTENING TORQUE
n
0.7 - 0.9N•m
13. INLET HARNESS/AC SWITCH
1 ) Disconnect four connectors, remove one screw A (M4 x 6, Silver), and remove the AC switch. Remove two screws B (M3 x 6 countersunk,
Black), and remove the AC inlet cable.
CAUTION
SCREW TIGHTENING TORQUE
n
Screw A: 0.9 - 1.1N•m
n
Screw B: 0.7 - 0.9N•m
Screw x 4
Connector x 4
Black
White
White
Blue
Confirm that the circle
(o) is on the left side
and it is in the OFF
(o) is on the left side
and it is in the OFF
Screw x 2
AC Inlet Cable
AC Switch
Mark
When attaching, ensure that the
terminals are oriented as
indicated in the engraved mark.
terminals are oriented as
indicated in the engraved mark.
A
Screw
x 1