PN-L602B (serv.man6) - Sharp Monitor Service Manual (repair manual). Page 20

Read Sharp PN-L602B (serv.man6) Service Manual online

PN-L702B/L602B INSTALLATION, ADJUSTMENT, SETTING
 2 – 1
CHAPTER 2.  INSTALLATION, ADJUSTMENT, SETTING
1. INSTALLATION
CAUTION
INSTALLING PRECAUTIONS
n
This product is for use indoors.
n
Since the monitor is heavy, consult your dealer before installing,
removing or moving the monitor.
n
When installing, removing or moving the monitor, ensure that this
is carried out by at least 4 people.
n
A mounting bracket compliant with VESA specifications is required.
Do not use any screw holes other than VESA holes for installation.
n
To attach a VESA-compliant mounting bracket, use M6 screws
that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the
thickness of the mounting bracket.
n
When moving the monitor, be sure to hold it with the handles both
on the rear and the unit bottom. Do not hold the LCD panel. This
may cause product damage, failure, or injury.
n
This monitor cannot be used in vertical orientation.
n
Use the monitor with the surface perpendicular to a level surface.
If necessary, the monitor may be tilted up to 20 degrees upward.
n
Mounting the monitor on the wall requires special expertise and
the work must be performed by an authorized SHARP dealer.
You should never attempt to perform any of this work yourself.
Our company will bear no responsibility for accidents or injuries
caused by improper mounting or mishandling.
n
This monitor should be used at an ambient temperature between
41°F (5°C) and 95°F (35°C). Provide enough space around the
monitor to prevent heat from accumulating inside.
n
If it is difficult to provide sufficient space for any reason such as
the installation of the monitor inside a housing, or if the ambient
temperature may be outside of the range of 41°F (5°C) to 95°F
(35°C), install a fan or take other measures to keep the ambient
temperature within the required range.
n
Temperature condition may change when using the display
together with the optional equipments recommended by SHARP.
In such cases, please check the temperature condition specified
by the optional equipments.
n
Do not use the product in locations where the unit is exposed to
direct sunlight or other strong light. Since this product operates
with infrared rays, such light may cause a malfunction.
n
Do not block any ventilation openings. If the temperature inside
the monitor rises, this could lead to a malfunction.
n
After mounting, please carefully ensure the monitor is secure,
and not able to come loose from the wall or mount.
n
Do not place the monitor on a device which generates heat.
n
Be sure to use a wall-mount bracket designed or designated for
mounting the monitor.
n
This monitor is designed to be installed on a concrete wall or pil-
lar. Reinforced work might be necessary for some materials such
as plaster / thin plastic board / wood before starting installation. 
This monitor and bracket must be installed on a wall which can
endure at least 4 times or more the weight of the monitor. Install
by the most suitable method for the material and the structure.
n
Fix the USB cable with the cable clamp (supplied).
1 Coil the cable into two loops approx. 1-9/16 inches (4cm) in
diameter at approx. 5-7/8 inches (15 cm) from the mini USB
connector.
2 Fix the loops to the fixing part above the USB port with the cable
clamp.
Unit: inch [cm]
7-7/8 [20]
2
[5]
2
[5]
2 [5]
1-7/16 [3.5]
2
1
Page of 127