PN-K322BH (serv.man6) - Sharp Monitor User Guide / Operation Manual. Page 29

Read Sharp PN-K322BH (serv.man6) User Guide / Operation Manual online

29
E
Controlling the Monitor with a PC (RS-232C)
MONITOR menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
MONITOR
STDR
WR
0-1
0-1 0: LANDSCAPE, 1: PORTRAIT
STANDBY MODE
STBM
WR
0-1
0-1 0: STANDARD, 1: LOW POWER
OFF IF NO OPERATION
ATOF
WR
0-1
0-1 0: OFF, 1: ON
TOUCH MODE AT STARTUP
POTM
WR
0-1
0-1 0: RESET, 1: NO RESET
-
MARK DISPLAY
TOUCH MARK 
DISPLAY
TMDT
WR
0-1
0-1 0: ALWAYS, 1: 5 S
-
CHANGE DISPLAY 
POSITION
TPOS
WR
0-3
0-3 0: RIGHT, 1: BOTTOM, 2: LEFT, 3: TOP
-
OTHERS menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
SCREEN 
MOTION
PATTERN
SCSV
WR
0,2,3
0,2,3 0: OFF, 2: PATTERN1, 3: PATTERN2
MOTION TIME 1
MTIM
WR
0-20
0-20
MOTION TIME 2
MINT
WR
5-20
5-20 Per second
POWER MANAGEMENT 
PMNG
WR
0-1
0-1 0: OFF, 1: ON
SIZE 
WIDE
WR
1-3
1-3 1: WIDE, 2: NORMAL, 3: Dot by Dot
MUTE AUDIO
MUTE
WR
0-1
0-1 0: OFF, 1: ON
-
INFORMATION MODEL
INF1
R
Value
SERIAL NO
SRNO
R
Value
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0
-
ADJUSTMENT LOCK
ALCK
WR
0-2
0-2 0: OFF, 1:ON 1, 2:ON 2
OSD DISPLAY
LOSD
WR
0-2
0-2 0: ON 1, 1: OFF, 2: ON 2
LED
OFLD
WR
0-1
0-1 0: ON, 1: OFF
TEMPERATURE ALERT
TALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
STATUS ALERT
SALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
VOLUME
VOLM
WR
0-31
0-31
BRIGHT
VLMP
WR
0-31
0-31
TEMPERATURE SENSOR
DSTA
R
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in 
standby mode
2 Internal temperature abnormal occurred (To delete the information of 
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is 
dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION  
ERRT
R
Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting
Page of 37