PN-K321 (serv.man15). New service tool and firmware - Sharp Monitor Technical Bulletin (repair manual). Page 2

Read Sharp PN-K321 (serv.man15) Technical Bulletin online

IDP 2013 06 05 
 
Date of Issue: 
24
th
 June 2013      
         
Classification: 
White 
IDP TECHNICAL BULLETIN
 
Page 2 of 4 
 
 
Sharp Electronics (UK) Limited 
Reference 
– PNF-A271
 
Revision  - 3 
 
White 
– Carry out as required 
Yellow 
– Carry out as required and whenever the unit comes in for service 
 Red 
– Carry out on all units   
 
ACTION 
Download the service tool from the technical website and follow the instructions 
provided below to update the main and sub firmware. 
 
 
Firmware update procedure using a USB memory stick 
 
USB MEMORY 
Use a USB memory stick corresponding to the following standards: 
  Format - FAT32 / FAT16 
  USB - 2.0 / 1.1 
  Recommended to use a USB memory stick with a read / write LED. 
Important notes 
  Set up an appropriate volume label name. 
  Using a SD card reader is unsupported. 
  Using a USB HUB is unsupported. 
  Do not use an encrypted USB memory stick. 
  Do not store any other files or folders in the USB memory stick. 
  If the version after rewriting is the same, the update will not start. 
  If the filename is changed, the update will not start. 
  Do not turn OFF the power or touch / remove the USB memory stick during the 
update. 
 
If the firmware update is performed with a USB memory stick where the firmware data 
of a different model is stored, the display cannot start up and cannot be recovered. 
When storing the firmware data to a USB memory stick, ensure the model name is 
correct. 
 