CHAPTER 7. TROUBLESHOOTING
PN-A601 TROUBLESHOOTING
7 – 3
2. OPTIONAL POWER IS NOT TURNED ON
3. THE REMOTE CONTROL DOES NOT WORK
Is the OSD setting properly configured?
No abnormality
No
No
Yes
No abnormality
Is 19V power output from the system power PWB?
Check the connected optional devices.
Configure the OSD setting again.
Replace the defective part.
Any problem with the Power Supply PWB
related items?
related items?
ȷIs the fuse blown?
ȷAny problem with the Power Supply PWB?
ȷAny problem with the Power Supply PWB?
Is the battery power alive?
Is the adjustment lock of "FUNCTION" set to [disabled]?
No abnormality
Yes
Yes
Consumption
No
No
Replace the battery.
Is the OSD set to non-display?
Set to ENABLE the OSD display (special function).
Clear the setting.
Is the control kit connected?
Yes
No
1
Is the control kit setting set to "External"?
Yes
No
Set the control kit to "External."
Replace the abnormal part.
Connect the cable to the proper terminal.
Connect the cable to the proper terminal.
Replace the abnormal part.
No abnormality
Abnormality
Abnormality
Any problem with the Control Kit or connection cable?
Any problem with the connection cable?
Any problem with the PWB?
Is the control kit cable is connected to the sound
terminal?
Any problem with the connection cable?
Any problem with the PWB?
Is the control kit cable is connected to the sound
terminal?
Check the I/F PWB and the related parts for any
abnormality.
Check the fuse for breakage.
Check the PWB.
abnormality.
Check the fuse for breakage.
Check the PWB.
1
Is the control kit setting set to "Built-in"?
Yes
No
Set the control kit to "Built-in."
Replace the abnormal part.
Replace the abnormal part.
No abnormality
Abnormality
Abnormality
Any problem with the key PWB or connection cable?
Any problem with the connection cable?
Any problem with the key PWB?
Any problem with the connection cable?
Any problem with the key PWB?
Check the I/F PWB and the related parts for any
abnormality.
Check the fuse for breakage.
Check the PWB.
abnormality.
Check the fuse for breakage.
Check the PWB.
Click on the first or last page to see other PN-A601 (serv.man3) service manuals if exist.