PN-465E (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 30

Read Sharp PN-465E (serv.man5) User Guide / Operation Manual online

E
28
Controlling the Monitor with a PC
Repeater control
This system has a function to allow setting of multiple 
monitors connected in a daisy chain using a single command. 
This function is called repeater control. You can use Repeater 
control function without assigning ID numbers.
[Example]
Set 1
Set 2
Set 3
Set 4
*   If monitors are connected as shown above, you can 
execute a command like “Set all monitors’ input settings to 
PC1 DIGITAL”.
Repeater control command
Repeater control is achieved by setting the FOURTH 
CHARACTER of the parameter to “+”.
Example:
VOLM030 +
Sets volume of all monitors to 30.
In repeater control, responses are returned by all the 
connected monitors.
If you want to determine that a value has been returned by a 
specific set, assign ID numbers to each monitor in advance.
When some monitors do not return their responses, the 
probable cause is that the monitors could not receive the 
command or command processing is not complete. Do not 
send a new command.
Example:  (When 4 monitors are connected, and 
assigned ID numbers: 1 through 4)
VOLM030 +
WAIT
OK   001
OK   002
OK   003
OK   004
← If 4 monitors are connected in 
a chain, reliable operation can 
be ensured by sending a new 
command only after a reply 
has been returned by 4th (last) 
monitor.
Repeater control can also be used for reading settings.
Example:
VOLM ? ? ? +
WAIT
10   001
Volume settings for all monitors 
are returned.
20   002
30   003
30   004
TIPS
•  If repeater control is used during ID designation (IDSL, 
IDLK), the ID designation is canceled.
•  Commands that use parameters consisting of more than 
four characters can not be controlled by repeater control.
Page of 39