PN-465E (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 26

Read Sharp PN-465E (serv.man5) User Guide / Operation Manual online

24
E
Initialisation (Reset)/Functional Restriction Setting
You can return the settings to their factory-preset values and 
restrict operations.
1.  After pressing 
SIZE
 for about 5 seconds, press 
 , 
 , 
 , and 
 in that order.
OFF
ON
ON
UNLOCKED
FUNCTION
1/1
ALL RESET
ADJUSTMENT LOCK
OSD DISPLAY
LED
RS-232C
END…[MENU]
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press 
 , select “ON” and then press 
MENU
 .
After initialisation, turn the main power switch off and 
then back on.
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
1 ........Disables all operations other than turning power 
on/off and FUNCTION.
2 ........Only the FUNCTION operation is enabled. 
Disables all operations other than FUNCTION (not 
even power on/off).
OSD DISPLAY
Hides/shows menus. 
The FUNCTION screen cannot be hidden.
ON ...........Displays the menus.
OFF .........Hides the menus.
LED
Specifies whether to light power LEDs.
ON ...........Lights power LEDs.
OFF .........Does not light power LEDs.
RS-232C
Specifies whether to allow control via RS-232C (see 
page 25).
LOCKED .............Disables control via RS-232C.
UNLOCKED........Enables control via RS-232C.
3.  Press 
MENU
 to return to the normal screen.