TROUBLE SHOOTING
5 – 1
CHAPTER 5. TROUBLE SHOOTING
A
The power cannot be turned on.
The LED lights up in green when
the POWER SW is turned on.
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
The backlight
lights up.
Check the input signals of
analog and digital cables.
Normal
Normal
Abnormal
Abnormal
Normal
Abnormal
Analog/digital
cable conversion
Check the inverter PWB.
When checking the output side, 
be careful of the high voltage.
(When starting: 1400V-rms)
Note:
Replace the LCD module lamp.
Replace the inverter PWB unit.
The inverter cable is connected.
The inverter cable is damaged.
Check the outputs on JP3 pins.
Replace the unit where an abnormality
occurs. (Main PWB, cable)
The LCD lights up in red.
The LED lights up in orange.
The LED is damaged.
Check the path between
JP2 (8pin) and U4 (120pin). 
The cable is disconnected.
Replace the unit where an abnormality
occurs. (Main PWB, SW PWB, cable)
The machine is in the power save mode
(the sync signal is not inputted).
The power of PC is turned off.
The RGB cable is disconnected.
The sync signal is not outputted
from the RGB cable.
The "Input" key is set to the analog,
digital, input PS side.
The sync signal is inputted to the main PWB.
Analog/digital cable
conversion.
Check the input signal.
AC adapter
Normal ?
Connected properly ?
+3.3V is applied to U4.
LED
The LED is not damaged.
Check the path between
J2 (8pin) and U4 (120pin).
The cable is disconnected.
Replace the abnormal unit. 
AC adapter
Main PWB
Switch PWB
Page of 22
Display