LL-193 (serv.man2). Complete - Sharp Monitor Service Manual (repair manual). Page 13

Read Sharp LL-193 (serv.man2) Service Manual online

LL-193A/LL-193G
CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 7
5.  LL-193A/G SERIES EDID WRITING PROCEDURES
[Target models of the tool]
LL-193A-B , LL-193A-W, LL-193G-B , LL-193G-W
[Operating environment of the tool]
•  Windows 95, Windows 98, Windows 2000, Windows XP
•  The I/O address of the printer port must be set to 378. 
(Refer to the additional explanation.)
[Installing procedures]
1) Create a folder (c:\fg)
2) Copy all the files in the launcher tool to the created folder (c:\fg).
(Be sure to use the launcher tool of the latest version.)
3) Copy all the files of the LL-193A/G EDID writing data to c:\fg.
[Operating procedures]
1) Connect the jig to the PC. (Refer to the connection diagram.)
2) Execute c:\fg\launchaer.exe.
3) The window is shown. Select [Classification] and [Process content] as follows:
[Classification]
[Process content]
After selection, press [EXECUTE] button. 
4) The window to check execution is displayed. If it is OK, press [Yes].
If not, press [No]. When [No] is pressed, the process returns to (3).
When [Yes] is pressed, the process goes to the next step. 
Note that the jig must not be connected to the monitor at that time. 
5) If the window below is displayed, check the following. 
1.
The jig is not connected to the PC properly.
2.
The jig is already connected to the monitor. 
Check the connection and click [OK] button to go to the next step.
6) The window below is displayed. Connect the jig to the monitor. 
Check the model name. 
[Setting on the monitor side]
1.  LL-193A series : Connect an RGB cable to the jig. 
LL-193G series  : Connect an RGB cable and  DVHD cable to the jig. 
2.  Press [POWER] key to turn on the power and wait until "No
input signal" is displayed. 
7) Enter the serial number with the keys and click [Next]. 
8) The window below is displayed. 
[In the case of the LL-193A-W, LL-193A-B]
[In the case of the LL-193G-W, LL-193G-B]
In the case of LL-193A-W, LL-193A-B
LL-193A
In the case of LL-193G-W, LL-193G-B
LL-193G
In the case of LL-193A-W, LL-193A-B
[LL-193A-W write EDID]
or [LL-193A-B write EDID]
In the case of LL-193G-W, LL-193G-B
[LL-193G-W write EDID]
or [LL-193G-B write EDID]
Page of 35
Display