TROUBLESHOOTING
7 – 2
POWER ABNORMALITY
*
Power flashing twice + OPC LED flashing
The following chart is OPC LED flashing pattern (1 cycle)
DET_10V error
Flashing Once
H:On
L: Off
DET_D3V3 error
Flashing twice
DET_12V error
Flashing 5 times
H:On
L: Off
H:On
L: Off
H:On
L: Off
Main error
Flashing 7 times
D3.3V does not rise up. Check the circuits 
around the connector PH - IC9602
A9V does not rise up. Check the circuits around 
the connector PH - IC9706.
Are the output 
voltages supplied from 
the power PWB?
No
Flashing 
several sec 
Immediately flashing
Abnormality
Abnormality
No abnormality
Check the inverter power. 
Check for blown fuse.
Check the power 
for signals.
Replace the abnormal parts.
Does the LED 
flashes immediately after 
AC_ON or does it light in blue and 
then flash several 
seconds after?
5V does not rise up. Check the circuits around 
the connector PH - IC9705.
PNL12V is not detected. Check the connector 
LP - PL - PC line. 
Check the fuse in the power interface PWB.
Main microprocessor detection error. For details, 
check the codes of ERROR SRNDBY CAUSE 
on 1/37 (North America) or 1/38 (Europe/China) 
of the process adjustment mode. For the errors 
corresponding to the codes, refer to 
■ MONITOR_ERR_CAUSE LIST"
DET_6V error
Flashing 3 times
H:On
L: Off
Page of 58