R-96 (serv.man3). R96ST Supplement refers to this - Sharp Home Appliance Service Manual (repair manual). Page 22

Read Sharp R-96 (serv.man3) Service Manual online

R-953/963M - 20
1
AN0
IN
Terminal not used. (For only R-953(SL)M/(W)M)
1
AN0
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input
is an analog input terminal from the AH sensor circuit, and connected to the A/D
converter built into the LSI. (For only R-963(SL)M/(W)M)
2
P77
OUT
Timing signal output terminal for temperature measurement(OVEN
THERMISTOR).
"H" level (GND) : Thermistor OPEN timing.
"L" level (-5V) : Temperature measuring timing. (Convection cooking)
3
P76
OUT
Timing signal output terminal for temperature measurement(OVEN
THERMISTOR).
"H" level (GND) : Thermistor OPEN timing.
"L" level (-5V) : Temperature measuring timing. (Convection cooking)
4-5
P75-P74
OUT
Terminal not used.
6
P73
IN
Signal coming from touch key.
When any one of G9 line keys on key matrix is touched, a corresponding signal
from P10, P11, P12, P13, P14, P15, P16 and P17 will be input into P73. When no
key is touched, the signal is held at "L" level.
7
P72
IN
Signal similar to P73.
When any one of G10 line keys on key matrix is touched, a corresponding signal
will be input into P72.
8
P71
IN
Signal similar to P73.
When any one of G11 line keys on key matrix is touched, a corresponding signal
will be input into P71.
9
P70
IN
Signal similar to P73.
When any one of G12 line keys on key matrix is touched, a corresponding signal
will be input into P70.
10-11
P57-P56
OUT
Terminal not used.
12
P55
OUT
Signal to sound buzzer.
A: key touch sound.
B: Completion sound.
C: When the temperature of the oven
cavity reaches the preset
temperature in the preheating mode,
or when the preheating hold time (30
minutes) is elapsed.
13-17
P54-P50
OUT
Terminal not used. (For only R-953(SL)M/(W)M)
13-17
P54-P50
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor). (For only
R-963(SL)M/(W)M)
18
P47
OUT
Terminal not used.
19
P46
IN
Input signal which communicates the damper open/close information to LSI.
Damper opened; "H" level signal (0V:GND).
Damper closed; "L" level signal (-5V:VC).
20
P45
OUT
Terminal not used.
21
P44
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay
(RY2). In 100% operation, the
signals hold "L" level during
microwave cooking and "H" level
while not cooking. In other
cooking modes (70%, 50%, 30%,
10%) the signal turns to "H" level
and "L" level in repetition
according to the power level.
LSI(IXA034DR)
The I/O signal of the LSI(IXA034DR) are detailed in the following table.
Pin No.
Signal
I/O
Description
ON/OFF time ratio in Mi-
cro cooking
(a. 32second time base)
ON/OFF time ratio in Mi-
cro cooking
(a. 48second time base)
MICRO
ON
OFF
COOK
100%
32 sec.
0 sec.
70%
24 sec.
8 sec.
50%
18 sec. 14 sec.
30%
12 sec. 20 sec.
10%
6 sec. 26 sec.
MICRO
ON
OFF
COOK
100%
48 sec.
0 sec.
70%
36 sec. 12 sec.
50%
26 sec. 22 sec.
30%
16 sec. 32 sec.
10%
8 sec. 40 sec.
A
B
C
H: GND
L
0.12 sec
2.4 sec
1.2 sec
1.2 sec
DESCRIPTION OF LSI
Page of 52
Display