R-952M - Sharp Home Appliance Service Manual (repair manual). Page 14

Read Sharp R-952M Service Manual online

R-952M  -  14
    SERVICING
transformer.
4) Re-install the outer case (cabinet).
5) Re-connect the power supply cord after the outer
case is installed.
6) Run the oven and check all functions.
A.
 On some models, the power supply cord between the
touch control panel and the oven itself is so short that
the two can't be separated.
For those models, check and repair all the controls
(sensor-related ones included) of the touch control
panel while keeping it  connected to the oven.
B.
 On some models, the power supply cord between the
touch control panel and the oven proper is long
enough that they may be separated from each other.
For those models, therefore, it is possible to check and
repair the controls of the touch control panel while
keeping it apart from the oven proper; in this case you
must short both ends of the door sensing switch (on
PWB) of the touch control panel with a jumper, which
brings about an operational state that is equivalent to
the oven door being closed. As for the sensor-related
controls of the touch control panel, checking them is
possible if the dummy resistor(s) with resistance equal
to that of the controls are used.
(2) Servicing the touch control panel with power
supply from an external power source:
Disconnect the touch control panel completely from
the oven proper, and short both ends of the door
sensing switch (on PWB) of the touch control panel,
which brings about an operational state that is equiva-
lent to the oven door being closed. Connect an
external power source to the power input terminal of
the touch control panel, then it is possible to check
and repair the controls of the touch control panel; it is
also possible to check the sensor-related controls of
the touch control panel by using the dummy resistor(s).
4. Servicing Tools
Tools required to service the touch control panel
assembly.
1) Soldering iron: 30W
(It is recommended to use a soldering iron with a
grounding terminal.)
2) Oscilloscope: Single beam, frequency range: DC -
10MHz type or more advanced model.
3) Others: Hand tools
5. Other Precautions
1) Before turning on the power source of the control unit,
remove the aluminium foil applied for preventing
static electricity.
2) Connect the connector of the key unit to the control
unit being sure that the lead wires are not twisted.
3) After aluminium foil is removed, be careful that abnor-
mal voltage due to static electricity etc. is not applied
to the input or output terminals.
4) Attach connectors, electrolytic capacitors, etc. to
PWB, making sure that all connections are tight.
5) Be sure to use specified components where high
precision is required.
E
C B
Transistor
2SB1238
Transistor
KRC243M
E
C
B
1. Precautions for Handling Electronic Components
This unit uses CMOS LSI in the integral part of the
circuits. When handling these parts, the following
precautions should be strictly followed. CMOS LSI have
extremely high impedance at its input and output terminals.
For this reason, it is easily influenced by the surrounding
high voltage power source, static electricity charge in
clothes, etc., and sometimes it is not fully protected by the
built-in protection circuit.
In order to protect CMOS LSI.
1) When storing and transporting, thoroughly wrap them
in aluminium foil. Also wrap PW boards containing
them in aluminium foil.
2) When soldering, ground the technician as shown in
the figure and use grounded soldering iron and work
table.
approx. 1M ohm
2. Shapes of Electronic Components
3. Servicing of Touch Control Panel
We describe the procedures to permit servicing of the
touch control panel of the microwave oven and the
precautions you must take when doing so.
To perform the servicing, power to the touch control
panel is available either from the power line of the oven
itself or from an external power source.
(1) Servicing the touch control panel with power
supply of the oven :
CAUTION:
THE HIGH VOLTAGE TRANSFORMER OF THE
MICROWAVE OVEN IS STILL LIVE DURING
SERVICING AND PRESENTS A HAZARD .
T
herefore, before checking the performance of the touch
control panel,
1) Disconnect the power supply cord, and then remove
outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power
transformer.
5) Ensure that these leads remain isolated from other
components and oven chassis by using insulation
tape.
6) After that procedure, re-connect the power supply
cord.
After checking the performance of the touch control
panel,
1) Disconnect the power supply cord.
2) Open the door and block it open.
3) Re-connect the leads to the primary of the power
Page of 28