FUNCTION OF IMPORTANT COMPONENTS
DOOR OPEN MECHANISM
The door can be opened by pushing the open button on the
control panel. When the open button is pushed, the open lever
pushes lower latch head on the door upward. The upper latch
head is linked with the lower latch head, so now, the  door can
be opened.
Figure D-1. Door Open Mechanism
MONITORED LATCH SWITCH SW1 AND STOP
SWITCH  SW3
1. When the oven door is closed, the contacts COM-NO of
each switch must be closed.
2. When the oven door is opened, the contacts COM-NO of
each switch must be opened.
MONITOR SWITCH  SW2
The monitor switch is activated (the contacts opened) by the
upper latch head on the door while the door is closed. The
switch is intended to render the oven inoperative by means
of blowing the fuse F2 F8A when the contacts of the moni-
tored latch switch SW1 fail to open when the door is opened.
LATCH
HEADS
LATCH HOOK
MONITORED LATCH
SWITCH
STOP SWITCH
OPEN LEVER
DOOR OPEN BUTTON
MONITOR 
SWITCH
FUSE F1 20A 250V
If the wire harness or electrical components are short-circuited,
this fuse F1 20A 250V blows to prevent an electric shock or fire
hazard.
FUSE F2 F8A 250V
1. If the wire harness or electrical components are short-
circuited, this fuse blows to prevent an electric shock or fire
hazard.
2. The fuse also blows when monitored latch switch SW1
remains closed with the oven door open and when the
monitor switch SW2  contact (COM-NC) closes.
3. The fuse also blows when the asymmetric rectifier, H.V.
rectifier, H.V. wire harness, H.V. capacitor, magnetron or
secondary winding of high voltage transformer is shorted
TC TRANSFORMER
TC transformer converts A.C. line voltage into low voltage to
drive the control unit.
THERMAL CUT-OUT TC1 150˚C (OVEN)
The thermal cut out protects the oven against overheat during
grill cooking, convection cooking or dual (combination) cook-
ing. If the temperature rises above 150˚C because the fan
motor is interrupted, the air inlet duct is blocked or the
ventilation openings are obstructed, the thermal cut-out opens
and switches off the all electrical parts.
When the oven cools itself down to the operating temperature
of 130˚C, the contacts of the thermal cut-out will close again.
THERMAL CUT-OUT TC2 125˚C  (MG)
This thermal cut-out protects the magnetron against overheat.
If the temperature goes up higher than 125˚C because the fan
motor is interrupted or the ventilation openings are blocked,
the thermal cut-out TC2 will open and line voltage to the high
voltage transformer T will cut off and operation of the magnetron
MG will be stopped. The defective thermal cut-out must be
replaced with a new one.
DUAL COOKING CONDITION
MICROWAVE AND BOTTOM GRILL (Figure O-5c)
Program the desired cooking time and then touch the
"BOTTOM GRILL"   
   and MICROWAVE keys (led's will
light on the display panel). When the START key is touched,
the following operations occur:
1. The numbers on the digital readout start the count down to
zero.
2. The oven lamp, cooling fan motor and turntable motor are
energized.
3. Relay RY4 is energized and the main supply voltage is
applied to the bottom heater.
4. Relay RY2 is energized and the microwave energy is
generated by the magnetron.
5. Now the food is cooked by microwave and bottom grill
simultaneously.
AUTO COOK
When the number keys are pressed (not in "MANUAL" 
mode). the oven chooses cooking mode (Microwave, Convec-
tion, Grill or Dual) and sets cooking time automatically accord-
ing to the pre-programmed information in IC-1 (LSI).
Function
1. When the door is opened, the contacts (COM-NC) of
monitor switch SW2 close (to the ON condition) due to their
being normally closed and contacts (COM-NO) open. At
this time the monitored latch SW1 is in the OFF condition
(contacts open) due to their being normally open contact
switches.
2. As the door goes to a closed position, the monitor switch
SW2 contacts (COM-NC) are opened and contacts (COM-
NO) closed  and then the monitored latch switch and stop
switch contacts close.(On opening the door, each of these
switches operate inversely.)
3. If the door is opened and the monitored latch switch  SW1
contacts fail to open, the fuse F2 (F8A) blows immediately
after closing of the monitor switch (COM-NC) contacts.
CAUTION: BEFORE REPLACING A BLOWN FUSE F2 F8A
TEST THE MONITORED LATCH  SWITCH,
MONITOR SWITCH  FOR PROPER OPERA-
TION.
(REFER TO CHAPTER “TEST PROCEDURE”).