11
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
3. If the high voltage fuse is blown, there could be a short in the high voltage rectifier or the magnetron.
Check them and replace the defective parts and the high voltage fuse.
4. CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE HIGH VOLTAGE FUSE WITH THE CORRECT VALUE REPLACEMENT.
1. CARRY OUT 3D CHECKS.
2. Disconnect the leads from the terminals of noise filter.
Using an ohmmeter, check between the terminals as described in the
following table.
MEASURING POINTS
INDICATION OF OHMMETER
Between N and L
Approx. 680 k
Between terminal N and WHITE
Short circuit
Between terminal L and RED
Short circuit
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS.
G
NOISE FILTER TEST
1. CARRY OUT 3D CHECKS.
2. If the fuse 20A is blown, there is a shorts or grounds in electrical parts or wire harness Check then and replace
the defective parts or repaire the wire harness.
3. CARRY OUT 4R CHECKS.
H
BLOWN FUSE 20A
1. CARRY OUT 3D CHECKS.
2. If the fuse F10A is blown when the door is opened, check the secondary interlock switch, relay RY1, relay
RY2 and monitor switch.
3. If the fuse F10A is blown by incorrect door switching, replace the defective switch(es) and the fuse F10A.
4. If the fuse F10A is blown, there is a shorts or grounds in electrical parts or wire harness.
Check them and replace the defective parts or repair the wire harness.
5. CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE FUSE F10A WITH CORRECT VALUE REPLACEMENT.
I
BLOWN FUSE F10A
FUSE
20A
N
L
LINE CROSS CAPACITOR   1.0
µ/AC275V 
NOISE SUPPRESSION COIL 
LINE BYPASS 
CAPACITOR
0.0047
µ/AC250V
LINE BYPASS
CAPACITOR
0.0047
µ/AC250V
RESISTOR   
10M    1/2W
RESISTOR   680K    1/2W
WHT
RED
NOISE FILTER
1. CARRY OUT 3D CHECKS.
2. A continuity check across the temperature fuse terminals should indicate a closed circuit unless the
temperature of the magnetron reaches approximately 150˚C. An open temperature fuse indicates overheating
of the magnetron. Check for restricted air flow to the magnetron, especially the cooling duct and cooling fan.
3. CARRY OUT 4R CHECKS.
CAUTION: IF THE TEMPERATURE FUSE INDICATES AN OPEN CIRCUIT AT ROOM TEMPERATURE,
REPLACE TEMPERATURE FUSE.
J
MAGNETRON TEMPERATURE FUSE TEST
1. CARRY OUT 3D CHECKS.
2. A continuity check across the thermal cut-out terminals should indicate a closed circuit unless the
temperature of the thermal cut-out reaches approximately 170˚C. The thermal cut-out resets automatically
at approximately 155˚C. If thermal cut-out has opened under normal condition, replace the same item as in
the parts list.
An open thermal cut-out indicates overheating of the top heating element unit. Check for restricted air flow
to the top heat element  unit through the vent holes of the oven cavity, especially the heater duct upper and
convection fan.
3. CARRY OUT 4R CHECKS.
CAUTION: IF THE THERMAL CUT-OUT INDICATES AN OPEN CIRCUIT AT ROOM TEMPERATURE,
REPLACE THERMAL CUT-OUT.
K
THERMAL CUT-OUT (TOP HEATER) TEST