R-772M (serv.man2) - Sharp Home Appliance Service Manual (repair manual). Page 19

Read Sharp R-772M (serv.man2) Service Manual online

19
30
P74
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47 terminal
while one of G3 line key on matrix is touched.
31
P73
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47 terminal
while one of G2 line key on matrix is touched.
32
P72
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47 terminal
while one of G1 line key on matrix is touched.
33
P71
OUT
Oven lamp and turntable motor driving signal(Square Waveform : 50Hz).
To turn on and off shut-off relay (RY1).
The square waveform voltage is
delivered to the relay (RY1) driving
circuit.
34
P70
IN
Connected to VC.
35
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily
set to "L" level the moment power is applied, at this time the LSI is reset. Thereafter
set at "H" level.
36
P81
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay
(RY2). In 100% operation, the
signals hold "L" level during
microwave cooking and "H" level
while not cooking. In other
cooking modes (70%, 50%, 30%,
10%) the signal turns to "H" level
and "L" level in repetition
according to the power level.
37
P80
OUT
Grill (TOP) heating element driving signal.
To turn on and off the grill heating
element relay (RY3). "L" level during
grill cooking, convection cooking or
dual cooking, "H" level otherwise.
The heater relay turns on and off
within a 48 second time base in
accordance with the special program
in LSI.
38
XIN
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XIN terminal.
39
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XOUT.
40
VSS
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
41
P27
OUT
Bottom heating element driving signal.
To turn on and off the relay (RY4). "L"
level during grill cooking, convection
cooking or dual cooking, "H" level
otherwise.
The heater relay turns on and off within
a 48 second time base in accordance
with the special program in LSI.
Pin No.
Signal
I/O
Description
During cooking
L
H
20 msec.
ON/OFF time ratio in Mi-
cro cooking
(a. 32second time base)
ON/OFF time ratio in Mi-
cro cooking
(a. 48second time base)
MICRO
ON
OFF
COOK
100%
32 sec.
0 sec.
70%
24 sec.
8 sec.
50%
18 sec. 14 sec.
30%
12 sec. 20 sec.
10%
6 sec. 26 sec.
MICRO
ON
OFF
COOK
100%
48 sec.
0 sec.
70%
36 sec. 12 sec.
50%
26 sec. 22 sec.
30%
16 sec. 32 sec.
10%
8 sec. 40 sec.
Power output
ON time
OFF time
100 %
48 sec.
0 sec.
90 %
44 sec.
4 sec.
80 %
40 sec.
8 sec.
70 %
36 sec.
12 sec.
60 %
32 sec.
16 sec.
50 %
26 sec.
22 sec.
40 %
22 sec.
26 sec.
30 %
16 sec.
32 sec.
20 %
12 sec.
36 sec.
10 %
8 sec.
40 sec.
Power output
ON time
OFF time
100 %
48 sec.
0 sec.
90 %
44 sec.
4 sec.
80 %
40 sec.
8 sec.
70 %
36 sec.
12 sec.
60 %
32 sec.
16 sec.
50 %
26 sec.
22 sec.
40 %
22 sec.
26 sec.
30 %
16 sec.
32 sec.
20 %
12 sec.
36 sec.
10 %
8 sec.
40 sec.
  DESCRIPTION OF LSI
LSI(IZA965DR)
The I/O signal of the LSI(IZA965DR) are detailed in the following table.
Page of 43
Display