R-761M - Sharp Home Appliance Service Manual (repair manual). Page 8

Read Sharp R-761M Service Manual online

8
761M -
PROCEDURE
LETTER
COMPONENT TEST
6-1. Touch "JACKET POTATOES" pad once.
6-2. The control panel is in the sensor cooking operation.
6-3. After approximately 25 seconds, push plunger of select switch for more than 3 seconds. This
condition is same as judgement by AH sensor.
6-4. After approximately 3 seconds, the display shows " X X . X X " which is the remaining cooking time,
and the display count down.
If the above is not the case, the control unit is probably defective.
If the above is proper, the AH sensor is probably defective.
R1,R2 :   22
 
±
 1% 1/2W
      R3 : 4.3k
 
±
 5% 1/4W
       R4 :   1M
 
±
 5% 1/4W
Sensor Dummy Resistor Circuit
Plunger
NC
NO
COM
COM
NO
NC
R3
R4
R1
R2
1
2
3
F-1
F-2
F-3
To connector (F)
on Control Unit.
CONNECTOR
TEST PROCEDURES
(3) Disconnect the wire leads from the cook relay.
(4) Disconnect the sensor connector that is mounted to lower portion of control panel.
(5) Then connect the dummy resistor circuit (see fig.) to the sensor connector of control panel.
(6) Reconnect the oven to the power supply and check the sensor cook operation, proceed as follows:
Page of 26
Display

Click on the first or last page to see other R-761M service manuals if exist.