R-61FBSTM - Sharp Home Appliance Service Manual (repair manual). Page 23

Read Sharp R-61FBSTM Service Manual online

R-61FBSTM/R-62FBSTM - 23
Figure C-3. Latch Switch Adjustments
below.
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads from the switches and control
panel.
3. Remove the control panel assembly from the oven cavity
front flange. Referring to chapter "CONTROL PANEL
ASSEMBLY REMOVAL".
4. Remove the one (1) screw holding the latch hook to the
oven flange.
5. Remove the latch hook assembly from the oven flange.
6. To remove the switch.
6-1. With pushing outward on the tab that is holding the
switch, turn the switch so that the post is an axis.(Monitor
Switch)
With pushing outward on the tab that is holding the
switch, slide  the switch out of the latch hook.(Stop
Switch and Monitored Latch switch)
6-2. Pull out the switch from the latch hook. Do not break the
post or tab of the latch hook.
6-3. Now the switch is free.
Re-install
1. Re-install each switch in its place. The monitored latch
switch is in the lower position and the monitor switch is
in the middle position. The stop switch is in the upper
position.
2. Re-connect wire leads to each switch. Refer to chapter
“Pictorial Diagram”.(page 29)
3. Secure latch hook (with one (1) mounting screw) to oven
4. Re-install outer case and check for microwave leakage
around the door with an approved microwave survey
meter. (Refer to Microwave Measurement Procedure.)
flange.
4. Re-install the control panel assembly to the oven cavity
front flange.
5. Re-connect wire leads to the control unit. Refer to
chapter “Pictorial Diagram”.(page 29).
6. Make sure that monitor switch is operating properly
and check continuity of the monitor circuit. Refer to
chapter “Test Procedure”, and Adjustment Procedure
Figure C-2. Latch Switches Removal
1. CARRY OUT 3D CHECKS.
     If the monitored latch switch, stop switch and monitor
     switch do not operate properly due to a misadjustment,
     the following adjustment should be made.
2. Loosen the one (1) screw holding the latch hook to the
flange of the oven front face.
3. With the door closed, adjust latch hook by moving it up
and down. In and out play of the door allowed by the
upper and lower position of the latch hook should be less
than 0.5mm.  The vertical position of the latch hook
should be adjusted so that the stop switch and the
monitored latch switch are activated with the door closed.
4. Secure the screw firmly.
5. Check the operation of all switches. If each switch has not
activated with the door closed, loosen screw and adjust
the latch hook position.
After adjustment, make sure of the following.
1. In and out play of the door remains less than 0.5mm when
in the latched position. First check upper position of latch
hook, pushing and pulling upper portion of door toward
the oven face. Then check lower portion of the latch hook,
pushing and pulling lower portion of door toward the oven
face. Both results (play in the door) should be less than
0.5mm.
2. The monitored latch switch and stop switch interrupt the
circuit before the door can be opened.
3. The monitor switch contacts (COM-NC) close when the
door is opened.
MONITORED LATCH SWITCH,  MONITOR SWITCH AND STOP SWITCH ADJUSTMENT
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
MONITORED LATCH SWITCH,  MONITOR SWITCH AND STOP SWITCH REMOVAL
Latch hook
Tab
SW3: Stop switch 
SW2: Monitor switch 
SW1:  Monitored latch switch 
Tab
Tab
Latch hook
SW3: Stop switch
Door
SW2: Monitor switch
SW1:Monitored latch switch
Latch heads
Page of 36
Display