R-341AM - Sharp Home Appliance Service Manual (repair manual). Page 7

Read Sharp R-341AM Service Manual online

R341M - 7
To protect the electronic circuits, this model is provided with a fine foil pattern added to the input circuit on the PWB, this foil
pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given below for repair.
Problem: POWER ON, indicator does not light up.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
The rated voltage is not applied between Pin
Check supply voltage and oven power cord.
No. 5 of the 3 pin connector (A) and the
common terminal of the relay RY2.
2
Only pattern at "a" is broken.
*Insert jumper wire J1 and solder.
3
Pattern at "a" and "b" are broken.
*Insert the coil RCILF2003YAZZ between "c" and "d".
NOTE: *At the time of making these repairs, make a visual inspection of the varistor. Check for burned damage. If
any abnormal condition is detected, replace the defective parts.
TEST PROCEDURES (CONT'D)
PROCEDURE
LETTER
COMPONENT TEST
D
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING BOARD
1
5
RY2
(J1)
a
d
c
b
CN-A 
RY1
D1
VRS1
D71
ZD71