R-341AM - Sharp Home Appliance Service Manual (repair manual). Page 3

Read Sharp R-341AM Service Manual online

R341M - 3
WARNING
Servicing and repair work must be carried out only by
trained service engineers.
The parts marked '*' on the parts list and schematic
diagram have voltages in excess of 250V.
Removal of the outer wrap gives access to potential
above 250V.
All the parts marked "
" on the parts list may cause undue
microwave exposure, by themselves, or when they are
damaged, loosened or removed.
CAUTION
MICROWAVE RADIATION
Do not become exposed to radiation from the
magnetron or other parts conducting microwave
energy.  All input and output microwave
connections, waveguides, flanges and gaskets must
be secured. Never operate the device without a
microwave energy absorbing load attached. Never
look into an open waveguide or antenna while the
device is energized.
WARNING
THIS APPLIANCE MUST BE EARTHED
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN
ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW : EARTH        BLUE : NEUTRAL        BROWN : LIVE
If the mains lead is replaced, only part number QACCBA032WRE3 should be used
SPECIFICATION
Power Requirements
230 -240 Volts     50 Hertz     Single phase, 3 wire earthed
Power Consumption
1.45kW
Power Output
900  watts nominal of RF microwave energy
(measured by way of IEC 705)
Operating frequency of 2450 MHz
Case Dimensions
Width 520 mm     Height 305 mm including foot     Depth 413 mm
Cooking Cavity Dimensions
Width 342 mm     Height 207 mm     Depth 368 mm
Turntable diameter
325 mm
Control Complement
Simple Touch Control System
Clock (1.00 - 12.59 or 0.00 - 23.59)
Microwave Power for Variable Cooking
Repetition Rate:
HIGH
 Full power throughout the cooking time
MEDIUM HIGH
 approx. 70% of FULL Power
MEDIUM
 approx. 50% of FULL Power
MEDIUM LOW
 approx. 30% of FULL Power
LOW
 approx. 10% of FULL Power
START/AUTO MINUTE pad
AUTO COOK/DEFROST pad
POWER LEVEL/WEIGHT pad
MORE/LESS pads
STOP/CLEAR pad
Time pads
Set Weight
Approx. 17 kg
 
   PRODUCT DESCRIPTION
CAUTION / WARNING
Page of 24
Display

Click on the first or last page to see other R-341AM service manuals if exist.