R-252M (serv.man2) - Sharp Home Appliance Service Manual (repair manual). Page 15

Read Sharp R-252M (serv.man2) Service Manual online

R-252M   15
1-2
VL2-VL1
IN
Power source voltage input terminal.
Standard voltage for LCD.
3-6
AN7-AN4
IN
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the
Model in operation is applied to set up its cooking constant.
7-8
P63-P62
OUT
Terminal not used.
9
AN1
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
10
P60
OUT
Terminal not used.
11-13
P57-P55
OUT
Terminal not used.
14
CNTR0
OUT
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
15
P53
OUT
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1).
The square waveform voltage is delivered
to the RY1 driving circuit and RY3 control
circuit.
16
P52
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY3).
The signals holds "L" level during
microwave cooking and "H" level while
not cooking. In other cooking modes
(variable cooking) the signal turns to "H"
level and "L" level in repetition according
to the power level.
(ON and OFF times for other power level.)
17-18
P51-P50
OUT
Terminal not used.
19
P47
OUT
Terminal not used.
20
P46
IN
Signal coming from touch key.
When either G12 line on key matrix is touched, a corresponding signal out of P20
- P27 will be input into P46. When no key is touched, the signal is held at "H" level.
21
P45
IN
Signal similar to P46.
When either G11 line on key matrix is touched, a corresponding signal will be input
into P45.
22
P44
IN
Signal similar to P46.
When either G10 line on key matrix is touched, a corresponding signal will be input
into P44.
23
P43
IN
Signal similar to P46.
When either G9 line on key matrix is touched, a corresponding signal will be input
into P43.
24
INT0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing
of LSI.
25
P41
OUT
Terminal not used.
26
P40
IN
Connected to VC through the pull-down resistor R90.
27
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily
set "L" level the moment power is applied, at this time the LSI is reset. Thereafter
set at "H" level.
28-29
P71-P70
OUT
Terminal not used.
  DESCRIPTION OF LSI
LSI(IZA954DR)
The I/O signal of the LSI(IZA954DR) are detailed in the following table.
Pin No.
Signal
I/O
Description
A
B
0.12 sec.
2.4 sec.
H : GND
L : -5V
H : GND
L : -5V
20.0 msec.
During cooking
H : GND
L : -5V
100P
H : GND
L : -5V
H : GND
L : -5V
70P
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
20.0 msec.
H : GND
L : -5V
Page of 35