R-252M (serv.man2) - Sharp Home Appliance Service Manual (repair manual). Page 13

Read Sharp R-252M (serv.man2) Service Manual online

R-252M   13
 
  TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
1. CARRY OUT 3D CHECKS.
2. Disconnect the leads from the primary of the high voltage transformer. Make sure that the leads
remain isolated from other oven components and chassis. (Use insulation tape if necessary.)
3. Close the door.
4. Reconnect the supply.
5. Check the voltage between Pin Nos. 1 and 3 of the 3 pin connector (A) on the control unit with an
A.C. voltmeter. The meter should indicate 230-240 volts, if not check oven circuit.
6. RY1 and RY3 TEST
These are operated by D.C. voltage. Check voltage at the relay coil with a D.C. voltmeter during
the microwave cooking operation.
DC. voltage indicated .............. Defective relay.
DC. voltage not indicated ........ Check diode which is connected to the relay coil. If diode is good,
control unit is defective.
RELAY SYMBOL
OPERATIONAL VOLTAGE
CONNECTED COMPONENTS
RY1
APPROX. 18.0V D.C.
Oven lamp / Turntable motor / Cooling fan motor
RY3
APPROX. 18.0V D.C.
High voltage transformer
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on
the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given
below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
The rated AC voltage is not present at
Check supply voltage and oven power cord.
POWER terminal of CPU connector (CN-A).
2
The rated AC voltage is present at primary
Low voltage transformer or secondary circuit defective.
side of low voltage transformer.
Check and repair.
3
Only pattern at "a" is broken.
*Insert jumper wire J1 and solder.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
4
Pattern at "a" and "b" are broken.
*Insert the coil RCILF2003YAZZ between "c" and "d".
(CARRY OUT 3D CHECKS BEFORE REPAIR)
NOTE: *At the time of these repairs, make a
visual inspection of the varistor for burn-
ing damage and examine the transformer
with tester for the presence of layer short-
circuit (check primary coil resistance). If
any abnormal condition is detected, re-
place the defective parts.
CARRY OUT 4R CHECKS.
M
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED
WIRING BOARD (PWB) IS OPEN
3
1
RY1
(J1)
a
b
c
d
VRS1
T1
CN - A
L
RELAY TEST
Page of 35