VENTA (serv.man11). Supplementary File Maintenance Operation Manual 1 - July 2002 - Sharp EPOS Service Manual (repair manual). Page 77

Read Sharp VENTA (serv.man11) Service Manual online

76
Programming
A number of new settings have been introduced in S2001.INI to allow this feature to
be configured :-
REM V46=========KITCHEN MONITOR==========
REM ==REQUIRES NETBUI PROTOCOL UPGRADE===
REM THE FOLLOWING SETTINGS SET THE ATTRIBUTES FOR THE KITCHEN MONITOR
REM REMOVE THE # BELOW TO SET THE OUTPUT PATH FOR THE KITCHEN MONITOR
REM SET FOR MASTER OR SLAVE ONLY NOT BOTH. ASSUMING MASTER = NODE001
REM MASTER SETTING ONLY
# KSCREEN=C:\KPM
REM SLAVE SETTING ONLY
# KSCREEN=S:\KPM
REM REMOVE THE # BELOW AND SET THE MONITOR HEADER FORMAT
REM SEE THE 4.6 MANUAL TO VIEW THE HEADER SWITCHES
# KSHEADER=MONITOR TEST %d/%m/%y %H:%M
REM SET THE KITCHEN PRINT (KP) OUTPUT TO A KITCHEN SCREEN (KPM)
REM KP SETTINGS SHOULD BE MADE AS NORMAL IN THE PRODUCT FILE
REM IF KP IS NOT REQUIRED DO NOT SET THE KP IN
REM TILL PARAMETERS OR PRINTER CONFIGURATION. IF THEY ARE SET THE
REM POS WILL PRINT ON THE KP AND THE KPM
# KP1=KS1
# KP2=KS2
# KP3=KS3
# KP4=KS4
# KP5=KS5
# KP6=KS6
# KP7=KS7
# KP8=KS8
# KP9=KS9
KSCREEN
This line should be set to indicate the data path of the Kitchen Monitor
system. As the monitor system has to access the POS for the data it is
a requirement that the master is set differently. The master should be
set to C:\KPM & the Slave to S:. This assumes the master will hold the
file TICKET.DAT in the directory \KPM. TICKET.DAT is used by the
Kitchen Monitor System.
Page of 89
Display