9. UPX200 Resetting Procedure
It may be necessary as a result of Battery Failure or Low Charge OR
Application corruption to carry out a FULL reset on the UPX200. This will
Application corruption to carry out a FULL reset on the UPX200. This will
effectively return the unit to a factory default. The procedure is a s follows :-
1. Whilst depressing the green on/off switch insert and depress gently the
stylus pen into the reset switch on the rear of the UPX200.
2. When the unit has switched off press the numeric 5 key and whilst
holding it down press the green on/off switch, after a few seconds
(approx 3) the unit will restart with a System Menu displayed.
3. Select Option 8 and press enter DOC Delete will be displayed with a
percentage complete.
4. Press any key followed by “0”. The unit will reboot and load the default
Operating System followed by the screen calibration utility.
5. Calibrate the screen and install the Application Software as above.