VENTA HANDHELD (serv.man6). Venta Supplementary Manual upto V4.4.0 - Sharp EPOS Service Manual (repair manual). Page 23

Read Sharp VENTA HANDHELD (serv.man6) Service Manual online

Sharp Electronics (UK) Ltd
Page 22 of 23
Venta
+
 Supplementary Manual – April 2007 – Version 4.4.0
15. 
When battery power is lost, the contents of the FlashDisk are protected (this includes the
Registry).
When power is restored (cold reset) the operating system attempts to start Venta+ (the
command to do this is stored in the (protected) registry).
The Venta+ start-up program (VPStartup.exe, in Flash) determines that Venta+ is no
longer installed and re-installs it from the CAB file stored in flashdisk
(\FlashDisk\VentaPlus.CAB).
It will then also re-install the most recent patch CAB from flashdisk, if available
(\FlashDisk\VentaPlusPatch.CAB).
It then copies back data (including configuration) from Flashdisk to the active program.
16. 
After battery power loss, the UPX200 loses its date/time settings. These must be restored
when battery power is available. Before Venta+ is re-installed from Flash following
battery power loss, the user will be prompted for the date and time.
R
R
E
E
G
G
I
I
S
S
T
T
R
R
A
A
T
T
I
I
O
O
N
N
1. 
The registration unlock code has now changed. If you are upgrading to Venta+ V4 from
an already registered (older version of Venta+) you will need to supply us with the “Lock
code” previously registered.
2. 
After confirming this with our records you will be supplied with the new Venta+ V4
“Unlock Code”.
U
U
P
P
X
X
2
2
0
0
0
0
 
 
R
R
E
E
S
S
E
E
T
T
T
T
I
I
N
N
G
G
 
 
P
P
R
R
O
O
C
C
E
E
D
D
U
U
R
R
E
E
It may be necessary as a result of Battery Failure or Low Charge OR Application corruption to
carry out a FULL reset on the UPX200. This will effectively return the unit to factory default. The
procedure is a s follows: -
1.  Whilst depressing the green on/off switch insert and depress gently the stylus pen into
the reset switch on the rear of the UPX200.
2.  When the unit has switched off press the numeric 5 key and whilst holding it down press
the blue on/off switch, after a few seconds (approx 3) the unit will restart with a System
Menu displayed.
3.  Select Option 8 and press enter DOC Delete will be displayed with a percentage complete.
4.  Press any key followed by “0”. The unit will reboot and load the default Operating System
followed by the screen calibration utility.