UP-X300 (serv.man71). UP-X300 Version History 1.6.0.13 (This document contains all the specification changes and Bug fixes upto version 1.6.0.13) - Sharp EPOS Driver / Update. Page 11

Read Sharp UP-X300 (serv.man71) Driver / Update online

11
12. Auto table feature is now working correctly, when the Recall feature is carried out  between Auto Table selection
13. Illegal characters no longer appear in the payment print line in cases where under bar (_) character in bold are used for descriptions
14. Deposits for customers are now stored in the customer file and therfore deposit refund can be carried out
15. In case the following two conditions are met the EOD was not correctly performed:- 1. The EOD report included the Clerk (Individual) and
the Clerk report was set to issue all PLU   2. EOD was executed more than two times without performing a "shutdown)
16. The length of a manually entered Backup/Restore filename is now limeted to the entry of 13 characters maximum
X300
V1.4.7.0
X200
V1.0.6.0
[Compatibility]
Only the CSV data is compatible with that of previous versions.
Do not install the new Version with “keep current data” or copy and paste existing "PRESET FOLDER" from older versions to
the new release version 1.4.7.0.
Please use the Back Office/Data control function a “Backup” of the current CSV Data and “Restore” it after the installation of
the OS and the application software.
This procedure is necessary due to some changes of the memory management of the new OS version.
[OS versions]
UP-X200 should be updated to OS version 1.23
UP-X300 should be updated to OS version 1.07
[Software version]
After OS update use only UP-X300 V1.4.7.0 or higher, in combination with UP-X200 version 1.0.6.0 or higher.
At an overlapped Clerk operation it possible again to void the first entered PLU.
It was previously not possible to operate  PLU/SUB and PLU name function in certain locally realised screen ( UK / Retail screen number 11)
The modifier and PLU search function is now working again, even so there is no “Item Key Area” in the screen of UP-X300
At the previous version, item count down function (86item function)  did not work in case the following programming was set as "No":
POS Programming / Function / Waste / Waste stock adjustment
Now the Count down (86item function) function works, regardless of the above setting.
KP printing stopped in case several KP printers were connected to one UPX300  and print data was send for each KP at the same timing.
In previous versions it was possible to change IP address of a terminal without performing MRS example change IP then select memory
Initialise caused error.
The registration screen could go blank if items were registered and the next key pressed was CANCEL. This bug has been corrected.
After EOD error (Open Check exist) if the operator chooses “Force to execute End Of Day” the terminal sales data is not cleared. The Sales
data is now cleared.
Page of 12
Display