UP-X300 (serv.man50). Updated 7 7 - Sharp EPOS FAQ (repair manual). Page 14

Read Sharp UP-X300 (serv.man50) FAQ online

A. The GT’s can only be removed by using special Print Layouts. These Print 
layouts and instructions can be found on the Sharp Technical website. 
 
3.4 Entry error server message  
Q. When I take an X report with a CCD report, When I sign back on and try 
and sell some items I get the message “entry error Server”. 
A. You need to perform a “Lock Clear”
 
 
3.5 EOS  
Q. How can I set the EOS to fire the Cash Drawer? 
A. Create a Macro which is: -  No Sale – EOS and set drawer to open at NS 
 
3.6 Electronic Journal  
Q. How can I clear down the EJ at EOD? 
A. Within POS Programming – Report Formats – End Of Day setting: set the 
Operation LOG data delete at Daily End Of Day to: Yes 
 
 
3.7 Electronic Journal  
Q. What happens when the EJ gets full 
A. The till will inform you that the EJ is full and you will need to perform an 
Operation/EJ Delete within POS Programming – System Setting – 
Administrator – Data Delete – Operation/EJ Delete. 
 
3.8 End of Session (EOS) Reports  
Q. Which reports are produced at End of Session? 
A. There is a maximum of 5 reports that can be produced; they are 
Transaction, Term, Hourly, PLU Hourly and Department. 
However for these to be produced they must also have been set for End of 
Day (EOD). 
 
 
3.9 Sales Data after Program Restore  
Q. What happens to the existing Sales Data in the X300, when carrying out a 
RESTORE Program.  
A. If the CLEAR Box is ticked at time of specifying the restore folder and the 
DELETE is selected at time of Restore the sales data in the X300 will remain, 
while new Program Data will be added. 
 
3.10 Cover Count or Guest# Counter on Sales Report  
Q. Is it possible to take a report that will show how many covers have been 
entered through the GUEST# key for Table entry?  
A. Yes, the “Sales by System (Consolidated)” report from the B/O will give 
you this figure. (See next FAQ). 
 
3.11 Guest Cover Count on Sales by System (Consolidated) Report  
Q. The Guest count figure in the report mention in Q3.10 is incremented by 1 
even when the GUEST# is not used.  
Page of 38