UP-X200 (serv.man23). Revision History X300 V1.5.0.6 and X200 V1.1.0.4 - Sharp EPOS Driver / Update. Page 3

Read Sharp UP-X200 (serv.man23) Driver / Update online

1. Employee Calculation Report has been added                                                     
Please note the report is only shown in B/O
2. Auto Shutdown and Reboot after EOD                                                       Dependent 
upon the setting within the configuration file the Terminal can be set to automatically 
shutdown and reboot after Manual EOD or Timed EOD is carried out, V1.4.11.1 is set to 
shutdown after manual EOD (added reliability/performance)  
3. Reboot button is added to the "Memory Warning" message screens
4. Partition Dismount at Manual Shutdown                                                             
Dependent upon the setting within the configuration file the HD2 partition will be dismounted 
at time of manual shutdown, to access HD2 at this point tap the screen 20 times. (added 
reliability/performance)
The following items 5 to 16 are resolved problems 
5. In case of bad wireless conditions buffered print jobs of x200 have often been issued twice, 
the message << reprint >> is now printed at top of receipts.
6. Long time to recover from suspend mode has been reduced.
7. Under certain conditions (2 past voids after expand feature causes windows CE or froze 
error) resolved.
8. Sort groups now correctly printed.
9. After editing manually the GT3 at B/O the calculation for GT1 is now correct.
10. BS is now working correctly with zero priced condiments linked to PLU with prices 
11. Leading PLU and their linked PLU's are now printed at KP even when they assigned to 
different sort groups 
12. Auto table feature is now working correctly, when the Recall feature is carried out  
between Auto Table selection
13. Illegal characters no longer appear in the payment print line in cases where under bar (_) 
character in bold are used for descriptions
14. Deposits for customers are now stored in the customer file and therfore deposit refund 
can be carried out
15. In case the following two conditions are met the EOD was not correctly performed:- 1. 
The EOD report included the Clerk (Individual) and the Clerk report was set to issue all PLU   
2. EOD was executed more than two times without performing a "shutdown)
16. The length of a manually entered Backup/Restore filename is now limeted to the entry of 
13 characters maximum
[Compatibility]
Only the CSV data is compatible with that of previous versions.
Do not install the new Version with “keep current data” or copy and paste existing 
"PRESET FOLDER" from older versions to the new release version 1.4.7.0. 
Please use the Back Office/Data control function a “Backup” of the current CSV 
Data and “Restore” it after the installation of the OS and the application software. 
This procedure is necessary due to some changes of the memory management of 
the new OS version.
[OS versions]
UP-X200 should be updated to OS version 1.23
UP-X300 should be updated to OS version 1.07
[Software version]
After OS update use only UP-X300 V1.4.7.0 or higher, in combination with UP-X200 
version 1.0.6.0 or higher.
Page of 4