UP-X200 (serv.man23). Revision History X300 V1.5.0.6 and X200 V1.1.0.4 - Sharp EPOS Driver / Update. Page 2

Read Sharp UP-X200 (serv.man23) Driver / Update online

3. Improvements of printer related issues:
a) Manually activate/de-activate alternative printers.
b) Possibility to delete stored error printing job (Administrator password)
For this entry the Administrator password must be changed to numeric code.(Currently as 
default it is changed to: 12345678 )
c) New additional KP assignment are realized:
   KP device assignment valid for a room
   KP device assignment valid for a terminal
4. The Customer file specification are enhanced :
a) The transfer of table data to the Customer file is realised.
(Also individual items can be transferred by the BS function).
b) For charge payments each VAT totalizer is stored in the customer file.
c) Print a complete customer’s bill via the F.E. application software. 
d) Customers Bills for a range of customer can also be issued.
5. Condiment PLU tables can be assigned to a Price level:
For each Condiment table a price level can be assigned, which is applied to all linked 
Condiment PLU’s.
6. The width of “scroll bar’s” at UP-X300 can be changed:
By “X300_StartUPMain2.ini” file setting it is now possible to change the width of the scroll bar. 
(Original width = 20 / Default setting is now =30)
Caution: Above change is only effective after the terminal is twice rebooted.
The changed width is applied to the registration window; BS screen; all pop up screens and to 
all BackOffice screens with scroll bars. 
The following items 7 to 12 are resolved issues:
7. Previously the “Taxable amount totalizer” was not updated in case a transaction was 
automatically finalized by removal of a Clerk key.
 
8. In case the “PLU Auto delete function” was executed at EOD it was previously still possible 
to register the deleted PLU at the Terminal (Front End application)
9. Send Print data was previously lost under the condition that the paper near-end check was 
set as "Yes" and the printer was switched off.
  
10. Modem connection was at the previous versions only working correctly at the UP-X300 
COM port 1. Now it works correctly  at all COM ports.
11. The initialization of a connected modem was previously not correctly performed. With 
Online activated at COM 2 or 3 a part of the initialisation command was still send to COM1.  In 
case a printer was connected to COM1 this sometimes resulted in a print of strange character.
12. The ATCOM.INI can now be modified via the BackOffice programming:
/POS Device programming/ Device programming / Online
Ensure the X300 OS is V1.07 and X200 OS is 1.23
Version 1.4.11.1 is compatable with 1.4.7.0 and above, please do not select "keep 
current data" if upgrading from a version older than 1.4.7.0, also do not copy and paste 
PRESET folder from versions older than 1.4.7.0
The following items 1 to 4 are specification changes or additions 
X300 
V1.4.11.1  
X200 
V1.0.10.0
Page of 4
Display