1 – 1
CHAPTER 1. PROGRAM RESET
1. CALIBRATION SETTING
1) Calibration setting starts in the following cases.
•  In case that the calibration operation for the touch key hasn’t done,
when  Set  the  reset  switch  to  ON  position  and  move  the  reset
switch to OFF position.
•  In case that Set the reset switch to ON position and move the reset
switch to OFF position with Pushing screen anywhere.
2) The Calibration setting window opens and starts.
Touch 5 points (cross marks) as display guidance.
3) After complete the Calibration setting, The menu window opens. 
(Selectable 2 keys, [PROGRAM RESET] and [MASTER RESET].)
2. PROGRAM RESETTING (INITIALIZATION)
1) Set  the  reset  switch  to  ON  position  and  move  the  reset  switch  to
OFF position.
In the time, if the calibration operation for the touch key hasn’t done,
execute the calibration operation.
2) The menu window opens. (Selectable 2 keys, [PROGRAM RESET]
and [MASTER RESET].)
Then select [PROGRAM RESET].
This resetting resumes the initial program without clearing memory.
3. MASTER RESETTING
By master resetting, ECR clears the entire memory and resume initial
values.
Master  resetting  can  be  accomplished  by  using  the  following  proce-
dures.
*
 Meanings of reset switch “ON” & “OFF” positions are as follows.
ON position:
The  position  that  CKDC  becomes  reset  state
(Reset status)
OFF position:
The position that CKDC becomes active state
(Normal status.)
*
 The secret number for the master resetting is follows.
MRS: 11111111
Caution: When turning ON the Reset switch (Reset), be sure to observe
the operation sequence of  “Power OFF --> Reset switch ON
(Reset) --> Power ON --> Reset switch OFF (Reset OFF)”. 
When resetting is made during the SDRAM writing operation, the mem-
ory may malfunction. 
PROCEDURE
1) Set  the  reset  switch  to  ON  position  and  move  the  reset  switch  to
OFF position.
In  this  time,  if  the  calibration  operation  for  the  touch  key  hasn’t
done, execute the calibration operation.
2) The menu window opens. (Selectable 2 keys; [PROGRAM RESET]
and [MASTER RESET])
Then select [MASTER RESET].
3) Enter the secret number.
4. LICENSE CONTROL
If the activation with expiration date for the license control has not been
effected  yet,  the  following  screen  is  displayed  after  master/program
resetting, or before the entering SRV mode by secret code.
ACTIVATION WITH EXPIRATION DATE
Following entry items has to be entered.
SERIAL NO:
The  serial  number  of  the  ECR  or  the  own  8-
digit number.
EXPIRATION DATE:
The  desired  expiration  date  of  the  first  activa-
tion (The format depends on SRV912A).
CURRENT DATE:
Adjustment of current date
(The format depends on SRV912A).
By pressing the “ENTER” key the following enquire appears.
If “OK” is selected the ECR will be activated until the entered expiration
date is reached.
And if the CURRENT DATE is modified, the system date is changed as
the  entered  date.  The  hour  and  minutes  of  the  system  time  are  not
changed. The second  is reset  as 00  at  the  time of pressing the “OK”
key. 
NOTE:
The programming of the date in the PGM2-mode is not possible after
the  activation  with  expiration  date  has  been  effected.  And  also  via
KAKOM only the time can be sent but the date cannot be transferred.
ARE YOU SURE? 
ACTIVATION WITH EXPIRATION DATE 
1.OK
2.CANCEL 