UP-3515 (serv.man3). UP3515 Program Manual (SRV lines etc) - Sharp EPOS Service Manual (repair manual). Page 10

Read Sharp UP-3515 (serv.man3) Service Manual online

3 – 4
[DEVICE CONFIG] - [13 BCR (SCANNER)
* ER-A6HS1 setting : “BAUD RATE = 4800 bps” , “DATA BITS = 7Bits”, “PARITY = ODD”, “STOP BIT = 1Bit”
[DEVICE CONFIG] - [14 SCALE]
[DEVICE CONFIG] - [15 ONLINE]
[DEVICE CONFIG] - [16 POLE DISPLAY]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-5
0
0:
 No RS232 channel is assigned.
1-5:  RS232 channel is assigned.
BAUD RATE
Transmission speed
4800 bps
4800 bps
9600 bps
19200 bps
DATA BITS
Data bit
7 Bits
7 Bits
8 Bits
PARITY
Parity bit
NON
ODD
EVEN
ODD
STOP BIT
Stop bit
2 Bits
1 Bit
1 Bit
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-5
0
0:
 No RS232 channel is assigned.
1-5:  RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-5
0
0:  No RS232 channel is assigned.
1-5: RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
WAITING TIME
Waiting time untilmessage is display-
yed on POLE.
0-999
0
3 digits (0 to 999 seconds) 
0 (No display)