C 2
Return to previous Model name
C 2.1
In order to avoid some misinterpreting of the model name by using
third party software, the model name has been changed from UP-
35xxV back to UP-3500V respectively UP-3515V. This model name is
visible in the System bar as well as in the ROM Version print out.
third party software, the model name has been changed from UP-
35xxV back to UP-3500V respectively UP-3515V. This model name is
visible in the System bar as well as in the ROM Version print out.
CCD error at Time-Out of Employee
C 2.2
Following setting have been made at the ECR:
•
‘Employee working time entry’ is set to COMPULSORY (SRV #987A)
•
‘Automatic Clerk SignOn after TimeIn/BreakOut’ and ‘Automatic Clerk SignOff after
TimeOut’ and ‘Employee and Clerk relationship is removed (i.e. Clerk Z is done)’ is set to YES
(SRV #987B).
TimeOut’ and ‘Employee and Clerk relationship is removed (i.e. Clerk Z is done)’ is set to YES
(SRV #987B).
•
‘Terminal CCD’ is set to YES (SRV #988D).
Under some circumstances, e.g. after a Service Reset, the Time-Out operation of an Employee after
the General-Z report has been carried out will result in the error ‘CCD NOT DONE’, even the CCD
entry has been made. This error is corrected since V1.62.
the General-Z report has been carried out will result in the error ‘CCD NOT DONE’, even the CCD
entry has been made. This error is corrected since V1.62.
Error “LACKING MEMORY” occurs during a Clerk SignOn
C 2.3
If a Clerk tries to make a SignOn at a Satellite while there is an active online communication via the
RS232 port of the Master with a PC, the error “LACKING MEMORY” may occur.
Since V1.62 the SignOn at the Satellite will not result in an error, even there is an active online
communication between the Master and a PC.
RS232 port of the Master with a PC, the error “LACKING MEMORY” may occur.
Since V1.62 the SignOn at the Satellite will not result in an error, even there is an active online
communication between the Master and a PC.
Drawer alarm does not work at the Satellite
C 2.4
If the SRV parameter #990A (open drawer at TimeOut of last Employee) is set to YES, a set drawer
alarm will not occur at the Satellite. This has been corrected with V1.62.
alarm will not occur at the Satellite. This has been corrected with V1.62.
Printing of TAX even the TAX amount is 0
C 2.5
If by SRV #905B the ‘TAX printing when TAX is 0’ is set to PRINT, the TAX amount was not printed
by mistake. This has been corrected with V1.62.
by mistake. This has been corrected with V1.62.
Missing VAT/TAX assignment print at Combo Tied-PLUs
C 2.6
In case the VAT/TAX assignment is set to the tied-PLUs at COMBO MEAL setting, the VAT/TAX
character was not printed. With V1.62, the VAT/TAX character will be printed as well at the Combo
tied PLUs according to their VAT/TAX relation.
character was not printed. With V1.62, the VAT/TAX character will be printed as well at the Combo
tied PLUs according to their VAT/TAX relation.